Decommisioning; Turn Off The Water Heater; Draining - AO Smith DRE 52 Manuel D'installation, D'utilisation Et D'entretien

Chauffe-eau tertiaire électrique

Publicité

Les langues disponibles

Les langues disponibles

EN
w
8.7
8.7.1
8.7.2
42
1
To start the water heater:
1.
Make sure that the water heater is not connected to the mains power supply.
2.
Open the door of the water heater.
Warning
Live cables inside! Switch off the power supply completely (on local isolator) before
opening the outer door to access the electrical components.
3.
Remove the isolating material.
4.
On each row of heating elements, turn the temperature control knob to the desired
temperature setting.
Setting
Temperature
O
57 °C
LO
60 °C
MED
72 °C
HI
83 °C
5.
Replace the isolating material.
6.
Close the door of the water heater.
7.
Connect the water heater to the mains power supply.

Decommisioning

To decommission the water heater:
1.
Turn off the water heater (see 8.7.1)
2.
Drain the water heater

Turn off the water heater

Refer to the procedure in the user part to Turn off the water heater (see 4.2) and isolate
the water heater from the mains power supply.

Draining

Refer to the installation diagram when you drain the water heater:
1.
If applicable, close the service stop valve (11) in the hot water pipe.
2.
If applicable, close the stop valves (4) of the circulation pipe (C).
1. Temperature control
knob
Installation, Maintenance and Service part