Special Vent Installation; Periscope Termination - Napoleon LV38N Instructions D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

12
SINGLE-SIDED OR
SEE-THROUGH
EN EN
3.3

SPECIAL VENT INSTALLATION

3.3.1 PERISCOPE TERMINATION

Use the periscope kit to locate the air termination above grade. The periscope must
be installed so that when fi nal grading is completed, the bottom air slot is located a
minimum 12" (30.5cm) above grade. The maximum allowable vent length is 10' (3m)
for a fi replace and 8' (2m) for a stove.
W415-1539 / B / 11.22.16
16" (40.6cm)
MINIMUM
40 FT (12M)
MAXIMUM
3 FT (1M)
MINIMUM
33"
(83.8cm)
24" (60.96 cm)
MINIMUM
33"
(838cm)
9.1B
12"
(30.5cm)
MIN TO
GRADE