MINIMUM CLEARANCE TO COMBUSTIBLES

COMBUSTIBLE FRAMING:
EN
Sides, back, bottom of the
appliance
COMBUSTIBLE FINISHING:
Sides
Enclosure Top
Recessed Depth
Sides of the vent pipe
Bottom of the vent pipe
Top of vent pipe
Ceiling
* HORIZONTAL VENT SECTIONS: A minimum clearance of 1" (25mm) at the bottom and 2" (51mm) at the top
and sides of the vent pipe in all horizontal runs to combustibles is required except for clearances in appliance
enclosures. Horizontal vent sections within enclosures require a minimum clearance of 18" (457mm) at the
top of the vent pipe. See "MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES" section. Use fi restop
spacer W010-1800 (supplied) where vent pipe penetrates combustible walls.
* VERTICAL VENT SECTIONS: A minimum clearance of 1" (25mm) all around the vent pipe on all vertical
runs to combustibles is required except for clearances in appliance enclosures. Vertical vent sections
within enclosures require a minimum clearance of 4" (102mm) to the sides of the vent pipe. See "MINIMUM
CLEARANCE TO COMBUSTIBLE ENCLOSURES" section. Use fi restop spacer W500-0367 (not supplied)
where vent pipe penetrates combustible ceilings or fl oors.
OUTSIDE
CHASE
40 3/4" 1035mm
20 1/4"
514mm
40 3/4" 1035mm
W415-1349 / A / 03.18.15
0" to stand-offs
2" (51mm) to front edge of the appliance
84" (2134mm) from the bottom of the appliance
20 1/4" (1276mm)
2" (51mm)*
1" (25mm)
2" (51mm)*
70" (1778mm) from the bottom of the appliance
20 1/4"
514mm
INSIDE
CHASE
2" 51mm
4" 102mm
2" 51mm
6" 152mm
4" 102mm
47"
1094mm
40 3/4" 1035mm
BACK WALL OF CHASE / ENCLOSURE
(INCLUDING ANY FINSIHING MATERIALS)
66 1/2" 1689mm
16 9/16"
421mm
33 1/4"
845mm