2.4
RATING PLATE INFORMATION
INSTALLATION AND OPERATING
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
For rating plate location, see "INSTALLATION OVERVIEW" section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appli-
ance and must be installed..
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIE CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
DIRECT VENT GAS FIREPLACE. SUITABLE FOR BEDROOM, BATHROOM AND BED-SITTING
ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN
ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS
EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED
HOME CONTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS
US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA
FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
FOR USE ONLY WITH BARRIER W565-0176. FOLLOW THE INSTALLATION INSTRUCTIONS
LOCATED IN THE INSTALLATION MANUAL.
Natural Gas/Gaz Naturel
HDX40NT
CHDX40NT
0-4500 FT (0-1370m)
40,000 BTU/h
26,000 BTU/h
MANIFOLD PRESSURE: 3.5" WATER COLUMN
PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 4.5" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE: 7.0" D'UNE COLONNE D'EAU
THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH
AIR FILTERS AND NOT FOR USE WITH SOLID FUEL. FOR USE
WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY
WARNING:
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER
WITH THE APPLIANCE.
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
TOP/ DESSUS
9½"
RECESSED DEPTH / PROFONDEUR D'ENCASTRE
FLOOR / PLANCHER
0
VENT SIDES / COTES DE L'EVENT
SIDES / COTES
2"
VENT TOP / DESSUS DE L'ÉVENT
BACK / ARRIERE
1"
VENT BOTTOM / DESSOUS DE L'ÉVENT
*
MANTLE / MANTEAU
13"
MAXIMUM HORIZONTAL EXTENSION / EXTENSION HORIZONTALE MAXIMALE: 2".
*
SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS. S E RÉFÉRER AU
MANUEL D'INSTRUCTION POUR DES EXTENSIONS PLUS GRANDES.
SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS.
SE RÉFÉRER AU MANUEL D'INSTALLATION DU PROPRIÉTAIRE POUR LES
LONGUEURS D'EVACUATION MINIMALE ET MAXIMALE.
WARNING:
IMPROPER IN
IMPROPER INSTALLATION,
KEEP BURNER AND CONTROL
ADJUSTMENT, T ALTER
ADJUSTMENT, ALTERATION,
L
COMPARTMENT CLEAN. SEE
SERVICE OR MAINTENANCE
SERVICE OR MAINTENANCE
R
CAN CAUSE PROPERTY DAMAGE,
AN CAUSE PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF
ERSONAL INJURY
R OR LOSS O
Y
INSTRUCTIONS MANUAL.
LIFE. REFER TO OWNER'S
LIFE. REFER TO OWNER'
APPLIANCE NEEDS FRESH
S FRESH
MANUAL. INSTALLATION AND
NUAL. INSTAL
T
AIR FOR SAFE OPERATION
OPERATION
A
SERVICE MUST BE PERFORMED
CE MUST B
AND MUST BE INSTALLED
E INSTALLED
T
BY QUALIFIED
BY A QUALIFIED INSTALLER,
WITH ADEQUATE PROVISIONS
ATE PROVISIONS
A
SERVICE AGENCY OR THE
SER CE AG
GAS SUPPLIER.
AS
FOR COMBUSTION
MBUSTION
AND VENTILATION AIR.
LATION
A
AIR.
ATTENTION:
UN INSTALLATION OU UNE
MODIFICATION INAPPROPRIEE
GARDEZ LE BRULEUR ET LE
DU REGLAGE, DU SERVICE ET DE
COMPARTIMENT DES
L'ENTRETIEN POURRAIENT ETRE
CONTROLES PROPRES.
LA CAUSE DE DOMMAGES A LA
CONSULTEZ LE MANUEL
PROPRIETE DE BLESSURES
D'INFORMATION ET
CORPORELLES OU MEME LA
D'INSTALLATION. PAR
MORT. CONSULTER LE MANUEL
MESURE DE SECURITE.
D'INFORMATION, L'INSTALLATION
CET APPAREIL DOIT
ET LE SERVICE DOIVENT
ETRE ALIMENTE EN AIR
ETRE EXECUTES PAR UN
FRAIS ET AVEC SUFFISANT
INSTALLATEUR QUALIFIE POUR
D'AIR COMBURANTET
LE AZ, UNE ENTREPRISE DE
DE VENTILATION.
SERVICE OU LE FOURNISSEUR
DE GAZ SEULEMENT.
FOYER À GAZ VENTILÉ DIRECTE. HOMOLOGUÉ POUR INSTALLATION DANS UNE
CHAMBRE À COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIÉPOUR
INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION EST CONFORME AUX
EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE MAISONS MOBILES ÉQUIPÉES
AU GAZ, EN VIGUEUR AU CANADA, OU AUX ÉTATS-UNIS, SELON LA NORME DE
SÉCURITÉ ET DECONSTRUCTIONDE MAISONS MANUFACTURÉES,TITRE 24 CFR,
SECTION 3280.DANS LE CAS OÙ CETTE NORME DES ÉTATS-UNIS NE PEUT ÊTRE
C E R T I F I E D
APPLIQUÉE, SE RÉFÉRER À LA NORME RELATIVE AU CRITÈRE DE MESURES DE SÉCURITÉ
CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉES,
LES SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A. POUR UNE UTILISER SEULMENT
AVEC BARRIÈRE W565-0176. SUIVEZ LES INSTRUCTIONS D'INSTALLATION SE
Propane
MODEL
HDX40PT
ALTITUDE / ELEVATION
0-4500FT (0-1370m)
INPUT / ALIMENTATION
36,000 BTU/h
REDUCED INPUT / ALIMENTATION REDUITE
26,000 BTU/h
MANIFOLD PRESSURE: 10" WATER COLUMN
PRESSION AU COLLECTEUR: 10" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 11" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE: 13" D'UNE COLONNE D'EAU
LE: E: 13" D'UNE COLONNE D'EAU
P.4: 56.6%
P.4: 56.6%
CE FOYER À GAZ VENTILÉS NE DOIT PAS ÊTRE UTILISÉ AVEC
TILÉS NE DOIT PAS ÊTRE UTILISÉ
S NE DOIT PAS ÊTRE UTILIS
DES FILTRES À AIR ET NE DOIT PAS ÊTRE UTILISÉ AVEC
R ET NE DOIT PAS ÊTRE UTILISÉ
UN COMBUSTIBLE SOLIDE. UTILISER AVEC LES PORTES
LE SOLIDE. UTILISER AVEC LES P
VITRÉES HOMOLOGUÉES AVEC CETTE UNITÉ SEULEMENT.
MOLOGUÉES AVEC CETTE UNITÉ S
OLOGUÉES AVEC CETTE UNITÉ S
AVERTISSEMENT:
ENT T : :
EN
N'A JOUTEZ
N'A
N'A JOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT
PAS
P
ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET
N N T T A A
T T T C C T T A A VE
A A A
VE
C C L L ES
E FLAMMES AUTRE Q Q UE C C E E LU
APPAREIL PAR LE FABRICANT.
AR LE E F F ABRICAN
F F F
ABRICAN
T T . .
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPAREIL DE CHAUFFAGE.
DÉCORATIF: NE PAS UTILISER COMME APPARE
TIF: NE PAS UTILISER COMME APPAR
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS. SEE OWNERS
LIANC
NCE E MU
M ST BE VE
VEN N TE
TED D U U SI SIN N G G T T H H E APP P R R OP
20½"
INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS
LL L A A TIO
A A
TIO
N N M M A A NU
NUA A L FOR VE
VEN N TI TIN N G G SPE
SPEC C IFI IFIC C S. S. P P R R OPE
NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM. L'APPAREIL DOIT É VACUER S E S
CESSA
ESSAR R Y Y
R R AFTER SE
AFTER SER R VICING G
R
THE VEN
THE VENT T -AIR IN
T T T
-AIR IN
2"
2"
GAZ
GAZ EN UTILISANT L'ENSEMBLE D'ÉVACUATION PROPRE À WOLF STEEL. SE RÉFÉRER AU M A N U E L
AZ E E N N U U TI TIL L ISA
ISAN N T T L L 'E 'EN N SE
S MBLE D D 'É 'ÉV V A A
V V V CU
CUA A TIO
A A A
TIO
D'INS
D'INST T ALL
D'INSTALLATION DU PROPRIÉTAIRE POUR LES SPÉCIFICATIONS DE L'ÉVACUATION. IL EST IMPORTANT
T T T
ALL
A A TION
A A A
TION
DU PROPRIÉ
DU
PROP
T
TAIRE
POUR LES SPÉC
POU
R LES SPÉ
1"
DE BIEN RÉINSTALLER ET RESCELLER L'ÉVENT APRÈS AVOIR EFFECTUÉ LE SERVICE DU SYSTÊME DE PRISE D'AIR.
D D E E BIE
BIEN N RÉ
R INSTALL LLE E R R ET ET R R ES
ESCELLER L'ÉVEN N T T AP
APRÈ
RÈS AV
ELECTRICA
ELECTRICAL RATING / CLASSIFICATION: 115V, 60HZ, LESS THAN 12 AMPS.
ELECTR
L R R A A TING / CLASSIFIC
A A A
TING /
A
ATION:
ON:
SPÉCIFICATIONS ÉLECTRIQUES : 115 V, 60 HZ, MOINS DE 12 A.
SPÉCIFICATIONS ÉLECTRIQUES : 115 V
SPÉCIFICATIONS ÉLE
OPTIONAL FAN KIT / SOUFFLERIE OP
OPTIONAL FAN KIT
OPTIONAL FAN KIT / SOUFFLERIE OPTIONNELLE :
HS.
HS.
GZ550-KT, GD65
GZ550-KT, GD65
GZ550-KT, GD65
S S
24 NA
24 NAPOLEON
24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 0G8 CANADA
SERIAL NUMBER/NO. DE SERIE:
SERIA
SERIAL NUMBER/NO. DE
L
UMBER/NO. D
HDX40
CAUTION:
ON,
HOT WHILE OPERATING. DO NOT TOUCH.
H
SEVE
SEVERE BURNS MAY RESULT. KEEP CHILDREN
CLOTHING, FURNITURE, GASOLINE OR
Y
OTHER FLAMMABLE VAPORS AWAY.
AVERTISSEMENT:
L'APPAREIL EST CHAUD PENDANT SON
FONCTIONNEMENT. BRÛLURES GRAVES
PEUVENT EN RÉSULTER. LES ENFANTS, LES
VETEMENTS, LES MEUBLES, L'ESSENCE ET
AUTRES LIQUIDES QUI EMETTENT DES GAZ
VOLATILS INFLAMMABLES DOIVENT
ETRE TENUS ELOIGNES DE L'APPAREIL.
This appliance is only for use with the the
type(s) of gas indicated on the rating plate
and may be installed in an aftermarket,
permanently located, manufactured home
(USA only) or mobile home, where not
prohibited by local codes. This appliance is
not convertible for use with other gases,
unless a certified kit is used.
Cet appareil doit être utilisé uniquement
avec les types de gaz indiqués sur la plaque
signalétique et peut être installé dans une
maison préfabriquée (É.-U. seulement) ou
mobile installée à demeure si les règlements
locaux le permettent. Cet appareil ne peut
être converti à d'autres gaz, sauf si une
trousse de conversion est utilisée.
TROUVENT DANS LE MANUEL D'INSTALLATION.
CHDX40PT
NE D'EAU
NE D'EAU
LUMN
UMN
D'UNE COLONNE D'EAU
D'UNE COLONNE D'E
ER COLUMN
R COLUMN
13" D'UNE COLONNE D'EA
DOIT PAS ÊTRE UTILISÉ
LISER AVEC LES P
A CET APPAREI
P
REI
L L AUCUN
AUCUN
LUI I Q Q
OPR R I I A A TE
A A A
TE
WO
WO
OPER R R R E
T T T
T T AKE SY
AKE S
N N P P R R OP
OP
S A
1
WOLF STEEL LTD.
W385-1993 / A
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS
AND LIQUIDS IN VICINITY OF THIS
OR ANY OTHER APPLIANCE.
DO NOT OPERATE
CAUTION:
THE FIREPLACE WITH THE GLASS
REMOVED, CRACKED OR BROKEN.
REPLACEMENT OF THE GLASS
SHOULD BE DONE BY A LICENSED
OR QUALIFIED PERSON.
POUR VOTRE
SECURITE:
NE PAS ENTREPOSER NI UTILISER
D'ESSENCE NI D'AUTRES VAPEURS
OU LIQUIDES INFLAMMABLES
ANS LE VOISINAGE DE CET
APPAREIL OU DE TOUT AUTRE
APPAREIL.
AVERTISSEMENT:
UTILISER L'APPAREIL SI LE
PANNEAU FRONTAL EN VERRE
N'EST PAS EN PLACE, EST CRAQUÉ
OU BRISÉ. CONFIEZ LE
REMPLACEMENT DU PANNEAU À UN
TECHNICIEN AGRÉÉ.
W415-1349 / A / 03.18.15
7
EN