Alcove Installation; Non-Combustible Facing Material - Napoleon HDX40NT-1 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.3

ALCOVE INSTALLATION

NOTE: Recesses or alcoves above the appliance can be made as deep as desired provided the minimum
clearances to combustibles are maintained.
Non-combustible material can be used, provided the minimum clearances to combustible materials are applied.
The minimum enclosure volume must be increased by no less than the volume of the recess. This adjustment
can be made by increasing any or all of the height, width and depth of the enclosure.
5.4

NON-COMBUSTIBLE FACING MATERIAL

WARNING: 2" (51mm) clearance from the surround is required for any material projecting out a maximum 2"
(51mm). If greater projections are desired, increase the clearance from the surround by 2" (51mm) for every 1"
(25mm) of additional projection.
RECESS OR
ALCOVE
AREA
ENCLOSURE
AREA
APPLIANCE
6" (152mm)
4" (102mm)
2" (51mm)
0" (0mm)
SAFETY
SCREEN
71.2
4"
(102mm)
3" (76mm)
2" (51mm)
TOP OF
APPLIANCE
DOOR
W415-1349 / A / 03.18.15
27
EN

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Hdx40pt-1

Table des Matières