Technical Specifications - mundoclima MUP-07 CN Instructions D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37

Technical specifications

Model
Outdoor unit R-407C
Capacities
Cool
Heat
Compressor
Refrigerant
Expansion/location
Power supply
Consumption
Nominal consumption
Start-up consumption
AM fuse
Outdoor noise level (3 m.)
Outer dia. condensed water drain pipe
Nett Weight
Type of connection
Tubing
Gas diameter
Liquid diameter
Maximum tubing length
Maximum elevation tubing
Refrigerant load KF
Refrigerant load KFR
Nominal cooling capacity is based on: Indoor air temp. = 27°C DB/19°C WB. Outdoor air temp. = 35°C DB, 4-meter tubing.
Nominal heating capacity is based on: Indoor air temp. = 21°C DB. Outdoor air temp. = 7°C DB/6°C WB, 4-meter tubing.
N = R-407C
All data and dimensions are subject to change without prior notice.
MUP-07 CN/HN
MUP-09 CN/HN
kW
2.0
kW
2.3
V.ph.Hz
kW
0.8
A
3.7
A
12
A
10
dB (A)
39
mm
Kg
25
3/8"
1/4"
m
15
m
10
g
580
g
650
MUP-12 CN/HN
MUP-16 CN/HN
2.5
3.5
2.8
3.8
Rotary
R-407C
Capillary/outdoor unit
230.1.50
0.97
1.3
4.4
6
23
30
10
10
39
44
16.5
32
40
Flared + Nut
3/8"
1/2"
1/4"
1/4"
15
15
10
10
950
800
950
1020
GB
MUP-21 CN/HN
MUP-24 CN/HN
4.5
6
4.9
7
1.7
2.6
7.7
11.3
40
64
16
20
48
51
40
59
1/2"
5/8"
1/4"
3/8"
20
20
15
15
1400
2000
1300
2200
7
7.5
3.2
15.4
75
25
54
75
5/8"
3/8"
30
20
2400
2500
19