5. Mount the wall mount plate, SP3200DR10, in the desired location. (Figure 4.12-3)
6. Connect the interface cable as shown in the 5.2 Wall Mounted Digital Control Interface Wiring diagram shown in
section 0 to the motor drive and user interface PCB. Use multi-conductor, jacketed cable suitable for the
installation location. The cable must be routed through the "DATA" conduit opening on the motor drive and
through the slot provided on the backside of the wall mount plate, SP3200DR10. Use a liquid tight cordgrip,
appropriately sized for the cable being used, to seal the conduit opening. Cable used may be up to 500 feet in
length. (Figure 4.12-3)
7. Mount the user interface to the wall mount plate, SP3200DR10, using the two screws. (Figure 4.12-3)
8. Apply power to the system and resume normal operation.
The following diagrams on the next page help illustrate the interface wall mounting procedure.
Page 12 of 76
Figure 4.12-1: Removing the Digital Control Interface for Wall Mounting
Figure 4.12-2: Adding the Blank Cover
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
HCP3000 SERIES Variable Speed Pump
ISHCP3000VSPC Rev -B