5.
Timer 1
+/- adjust;
6.
Timer 1
8:00a to 6:00p
7.
Choose Days
7D 7 days a week
Note: When start/stop times are set to be the same, the timer is deactivated. Each timer can be set to run on
specific days of the week. Options are to run 7 days per week, 5 days per week (Monday thru Friday), or on a single
day (Monday thru Sunday). Each timer is set up in this same manner. When the pump is powered and the timers are
set up, the Timers Active LED will illuminate. If the timers are set up such that their run times overlap, the timers will
run in priority from Timer 1 to Timer 8. In other words, if Timer 1 is set to run from 8:00 am to 12:00 pm, and Timer 2
is set to run from 10:00 am to 2:00 pm, the pump will run Timer 1 from 8:00 am to 12:00 pm, and will then switch to
run Timer 2 until 2:00 pm. Default setting for Timer 1 is to start at 12:00 am, and end at 11:45 pm. When Remote
Control Mode is set to Relay Control, the speed for Timer 1 may be set to 0 rpm to allow the pump to be stopped
without having to remove power.

6.8 Preset Speed Setup Menu

1.
Speeds Menu
Press > to enter
2.
Speed 1 Name
3.
Speed 1 Duration
0:30 hours
Note: Each time a preset speed is selected, it will run for the programmed duration. Multiple presses of the speed
button will add more time according to the set duration up to a maximum of 12 hours.
4.
Speed 1 Speed
1725 (600-3450rpm)
Note: Preset Speed settings can also be quickly updated without entering the Speeds Menu using the + and - arrow
buttons to change the speed and then pressing the > button to save the new speed setting.
Page 22 of 76
1725rpm
times >
1725rpm
>
Screen
Speed 1
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
HCP3000 SERIES Variable Speed Pump
+ -
Use to set speed for timer
< >
Use > to set start/stop time
+ -
Use to set start/stop time for timer
< >
Use > to choose days of operation for timer
+ -
Use to choose days of operation for timer
< >
Move to next menu item
Buttons
Used
Comments
< >
Use > to enter Speeds Menu
+ -
Use to rename displayed speed
< >
Move to next menu item
+ -
Use to set duration of speed
< >
Move to next menu item
+ -
Use to set motor speed for displayed speed
< >
Move to next menu item
ISHCP3000VSPC Rev -B