4.13 Installation Procedure
Please review sections 4.1 through 4.12 before continuing with this section.
1.
TURN OFF THE ELECTRICAL POWER AT THE CIRCUIT BREAKER.
2. Remove the wiring access cover on the motor drive.
3. Connect 230VAC line power supply wiring to the terminal block and ground screw as shown in the 5.1 Input
Power/Motor Wiring diagram. Wiring must be routed through the conduit opening labeled "POWER". See section
5.1 for diagram.
4. If the pump will be controlled using a Hayward pool control, connect a two-conductor cable as shown in the 5.3
Hayward Control Wiring diagram. See section 5.3.
5. If the pump will be controlled using relay contacts from an external control, connect the INP1-INP3 and 12VAC
power out terminals to the external relays as shown in the External Relay Speed Control Wiring diagram. See
section 5.4 and 0.11.
6. If the installation will use the remote stop feature of the drive, connect INP4 and 12VAC power out terminals to
the remote stop switch as shown in the Remote Stop Wiring diagram. See section 5.5.
7. Wiring for remote control and/or remote stop functions must be routed through the conduit opening labeled
"DATA". Use a multi-conductor, jacketed cable suitable for the installation location. Use a liquid tight cordgrip,
appropriately sized for the cable being used, to seal the conduit opening.
8. Connect the pump to the pool bonding system using 8AWG (6AWG for Canada) wire. A lug for bonding is
provided on the outside of the drive enclosure.
9. After all electrical connections have been made, replace the wiring access cover on the motor drive ensuring that
the motor lead wires are routed such that the wiring access cover can be installed and seated fully without
interference. Tighten the supplied screw on the access cover.
Note: The wiring access cover must be installed properly to provide environmental protection for the wiring
compartment.
10. Apply power to the system, and proceed to "6.6 Configuration Menu", section 0.
Page 13 of 76
Figure 4.12-3: Wall Mounting the Interface
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
HCP3000 SERIES Variable Speed Pump
ISHCP3000VSPC Rev -B