DESCRIPTION
L
N
Battery
Motor MASTER
Motor SECOND
24V/150mA
MASTER
Motor1
BRN
GRN
WHT
YEL
SECOND
Motor2
BRN
GRN
WHT
YEL
"Key symbol"
COM
PHOTO1
PHOTO2
COM
STOP 8.2KOhms
E-lock symbol
INPUT 24VAC
Transformer 230VAC
250V/2A
PHOTOCELLS (OPTIONAL)
The photocells are for safeguarding the gate and must be used. The
fitting location depends on the gate's design. EN12453 specifies that a
pair of photocells must be installed at a height of 200 mm and activated
to "Close". The photocells consist of a transmitter and a receiver and
must be opposite each other. The photocell is mounted on the wall
using small screws and wall plugs. To enable the "Automatic Closing"
function, the Chamberlain failsafe photocell must be installed. The
Chamberlain failsafe system (2-cable system) has small LEDs (light)
that can be seen from the outside on both sides to indicate the status
of the photocell.
Diagnosis at the Chamberlain failsafe photocell
LED constant = OK
LED flashes = photocell disables control board
LED off = no current, incorrect connection or polarity
Diagnosis on the control board
LED PHOTO1, 2 off = OK no photocell connected
LED PHOTO1, 2 on constantly = OK
LED PHOTO1, 2 flashes = photocell disables control board
FUNCTION
Connector L 230V supply
Connector N 230V supply
Connector for a battery kit +/-
475E + 041ADBL-0115
motor 1 (master opens first)
motor 2 (Second opens second)
Flashing light (accessory)
brown cable
green cable
white cable
yellow cable
brown cable
green cable
white cable
yellow cable
key switch
negative pole
Photocells 1
Photocells 2
negative pole
connector for emergency switch or
safety edge with 8.2KOhms
connection for E-lock control board
24V power input from transformer.
Can be connected with any polarity.
230V supply to transformer. Can be
connected with any polarity.
Fuse 250V/2A (2x included)
+
-
-
+
DESCRIPTION OF PUSH BUTTONS
P1 button to program "simple" mode
P2 button to program "individual" mode
P3 button to program "Timer to close"
Description of LED's (light-emitting diode)
Description
Colour
STOP/8.2KOhms
green
"Key symbol"
red
PHO2
red
PHO1
red
LEARN
yellow
DIAGNOSTIC
red
Only modify settings when control bord
is disconnected. Otherwise modifications will
not be accepted!!!
COM PHOTO
COM STOP/*
1
2
Function
monitors emergency switch
or safety edge
ON: blocks control board
OFF: OK
key switch
ON: key switch is operating
OFF: key switch is not
operating
Photocells 2
ON: OK (active)
OFF: no photocell fitted
Photocells 1
ON: OK (active)
OFF: no photocell fitted
learn mode indication
ON: learn mode active
OFF: learn mode inactive
diagnosis mode
Refer to FAQ's
8.2 Ω
8.2
Ω
+
+
+
+
+