TECHNICAL DATA OF MOTOR CONTROL:
Voltage
Transformer
Output motor
Supply accessories
Operating temperature
Degree of protection
PE
TRANSFORMER
230VAC
250V/2A
L
N
POWER SUPPLY
230VAC/50Hz
230VAC
PE
230VAC
230/24VAC minimum60VA
24VDC max.
24VDC - 100mA
-20°C - +55°C
IP54
INPUT 24VAC
MOTOR
MOTOR
30VDC
MASTER
SECOND 24V/150mA
+ -
WIRING OF CONTROL / SUMMARY
a) start with still dead 230Volts supply cable on the left side of the box.
b) Attach cable eye to ground wire. Then connect ground wire to base
plate with washer and nut (exactly as shown in picture detail).
Connect all other cables to control.
c. For the drives: Use cables which are suitable for outside use
(Thickness: 0,75mm²). If needed, use the same cable twice.
Attention:Check repeatedly that cable colours are connected correctly
to motor. Otherwise motor might be damaged or will not operate
properly. Pay special attention when using distribution boxes.
We recommend the following accessories: LA400-JB40E Kit for
cable extension of one installation unit. Consists of 12m of
cable 6-pole with identical colours, distribution box IP65,cable screw
joints and fastening material