Timed Blower; Manual Operation - Napoleon WHD48N Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

36
8.12

TIMED BLOWER

NOTE: This function is not available as the appliance is not equipped with a blower.
EN
Your remote system may have a built in timer (in thermostat mode) that enables the blower (if equipped) to
cycle on and off automatically when the burner turns on and off. With the remote control fan speed preset at
the preferred speed, the blower will come on approximately 5 minutes after the main burner comes on and
will shut off approximately 12 minutes after the burner shuts off.
This time delay is designed to maximize the blower distribution of heated air.
If at any time the burner re-ignites before the twelve minutes are over, the fan will continue to run.
NOTE: At any time in the sequence, the blower (if equipped) can be manually turned on/off using the
remote control.
8.13

MANUAL OPERATION

The appliance can be manually overridden
by the remote receiver switch located either
on the right side of the appliance or hard
wired into the wall. If necessary, change the
operation from 'REMOTE' by either sliding the
switch up to 'ON' or down to 'OFF'.
NOTE : 'ON' and 'OFF' on the remote
receiver only controls the gas.
W415-1606 / 09.09.16
35.19B

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Whd48p

Table des Matières