30
7.0 ELECTRICAL INFORMATION
7.1
HARD WIRING CONNECTION
It is necessary to hard wire this appliance.
EN
Permanently framing the appliance with an enclosure, requires the appliance junction box to be hard wired.
This appliance must be electrically connected and grounded in accordance with local codes. In the absence
of local codes, use the current CSA C22.1 Canadian electrical code in Canada or the ANSI/NFPA 70-1996
National electrical code in the United States.
7.2
WIRING DIAGRAM
This appliance comes equipped with a battery back-up. If this backup is used install four AA batteries (not
supplied) into the holder and connect to the wire harness. The connection point resembles a 9 volt battery type
of terminal, however, a 9 bolt battery must not be connected.
BATTERY HOLDER COMPLETE
WITH RESET BUTTON
W415-1606 / 09.09.16
DO NOT WIRE 110 VOLTS TO THE VALVE OR WALL SWITCH.
PILOT
OPTIONAL
NOT SUPPLIED
RESET
BUTTON
WARNING
!
W190-0048 (RECEIVER)
* BLOWER NOT
AVAILABLE WITH THIS
APPLIANCE