THESE INSTRUCTIONS ARE TO BE USED IN CONJUNCTIONS WITH THOSE FOR THE GPV AND THE APPLIANCE.
THIS INFORMATION SUPERSEDES THAT IN THE APPLIANCE INSTALLATION INSTRUCTIONS.
CONSUMER: RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Included in this kit:
W750-0127
Wire, 14" (355.6mm) jumper
W750-0285
Wire harness, unit (Electrical Box)
W750-0291
Wire, Switch
W500-0674
5" Restrictor Plate
W175-0309
Connector, reducer 5/8" to 4/7"
NOTE: If you have a circulation blower installed, you will
need to have additional power installed for the operation
of the power vent system.
TERMINAL INSTALLATION
REFER TO GPV INSTALLATION INSTRUCTIONS.
WIRING DIAGRAM AND INSTALLATION
REFER TO GPV INSTALLATION INSTRUCTIONS SECTIONS "SIT 880/886 NOVA FOR USE WITH SINGLE POLE
SWITCH, COMPLETE WITH GPV POWER VENT TERMINAL" OR "SIT 820 NOVA MILLIVOLT FOR USE WITH SINGLE
POLE SWITCH, COMPLETE WITH GPV POWER VENT TERMINAL."
VENTING INSTALLATION
USE ONLY WOLF STEEL APPROVED VENTING COMPONENTS.
REFER TO THE APPLIANCE INSTALLATION INSTRUCTIONS FOR ASSEMBLY AND CLEARANCE REQUIREMENTS.
VENTING LENGTHS
When installing the venting, these parameters supersede the "Vent Installation Section" in the appliance's "Installation
and Operating Instructions," as well as the following guidelines:
All venting confi gurations apply to both top and rear vented units.
Maximum vent run is 60 feet (18.3m) total.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada •
PVA-58ASCENT POWER VENT ADAPTOR KIT
INSTALLATION INSTRUCTIONS
(5/8" ASCENT SERIES)
INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE.
1(866)820-8686
www.napoleon.com
W415-2981 / 01.06.21

Publicité

Table des Matières
loading

Sommaire des Matières pour Napoleon PVA-58ASCENT

  • Page 1 Operating Instructions,” as well as the following guidelines: All venting confi gurations apply to both top and rear vented units. Maximum vent run is 60 feet (18.3m) total. W415-2981 / 01.06.21 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...
  • Page 2 Multi-elbow installations are possible up to a maximum of six 90°. V1+V2+V3+ V1+V2+V3+ ELBOWS H1+H2+H3 H1+H2+H3 60 FEET (18.3M) 10 FEET (3.1M) SIX 90° W415-2981 / 01.06.21 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...
  • Page 3: Restrictor Plate Installation

    Restrictor Restrictor Exhaust collar Firebox top #8x½ hex head sheet metal screw 1. Most restriction 2. Moderate restriction 3. Least restriction W415-2981 / 01.06.21 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...
  • Page 4 VALVE VALVE ELECTRONIC IPI / CPI IPI BOARD GROUND EYELET GROUND DC SUPPLY YELLOW YELLOW Switch/Thermostat (not supplied) Remote Receiver (not supplied) W415-2981 / 01.06.21 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...
  • Page 5: Installation De La Terminaison

    Toutes les confi gurations de ventilation applicables aux deux unités ventilés supérieur et arrière. La déviation maximale est de 60 pieds (18.3m) en tout. W415-2981 / 01.06.21 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...
  • Page 6: Évacuation Sur Le Dessus, Configuration Simple

    90°. V1+V2+V3+ V1+V2+V3+ COUDES H1+H2+H3 H1+H2+H3 MAXIMUM MAXIMUM MINIMUM 60 PIEDS (18.3M) 10 PIEDS (3.1M) SIX 90° W415-2981 / 01.06.21 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...
  • Page 7: Évacuation Verticale Descendante

    L’haut de la chambre de Vis muni combustion Restriction Restriction Le col d’évacuation L’haut de la chambre de Vis métallique de #8x½ à combustion tête hexagonale W415-2981 / 01.06.21 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...
  • Page 8 PANNEAU IPI ANNEAU DE MISE À LA TERRE MISE À LA TERRE DC SUPPLY JAUNE JAUNE Thermostat/Interrupteur Interrupteur (non fourni) Récepteur (non fourni) W415-2981 / 01.06.21 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...

Ce manuel est également adapté pour:

W750-0127W750-0285W750-0291W500-0674W175-0309

Table des Matières