Split Flow Valve; Timed Blower; Anti Condensation Control Switch - Napoleon XIR3N Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.2.13 SPLIT FLOW VALVE

The split fl ow function controls the ability to turn ON/
OFF a second burner.
A.
Use the mode key to guide you to the split fl ow
function.
B.
Pressing the up arrow key will activate the
second burner.
C.
Pressing the down arrow key will deactivate the
second burner. A single "beep" will confi rm the reception of the command.
NOTE: There is no way to modulate the fl ame heights separately.

6.2.14 TIMED BLOWER

Your remote system may have a built in timer (in thermostat mode) that enables the blower (if equipped) to
cycle on and off automatically when the burner turns on and off. With the remote control fan speed preset at
the preferred speed, the blower will come on approximately 5 minutes after the main burner comes on and
will shut off approximately 12 minutes after the burner shuts off.
This time delay is designed to maximize the blower distribution of heated air.
If at any time the burner re-ignites before the twelve minutes are over, the fan will continue to run.
NOTE: At any time in the sequence, the blower (if equipped) can be manually turned on/off using the
remote control.
6.3

ANTI CONDENSATION CONTROL SWITCH

This appliance has the option to go from an electronic intermittent
pilot ignition to a standing pilot for cold climates.
76
°F
OFF
35.17A
35.19B
(OPERATING SIDE)
ANTI CONDENSATION
CONTROL SWITCH
21
76
°F
ON
RIGHT SIDE OF
DOOR FRAME
W415-1343 / A / 11.18.16
EN

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Xir3p

Table des Matières