Removing the saw blade
1. Turn the chuck (9) as far forward as
possible and hold it firmly in this posi-
tion.
2. Remove the saw blade (15/16) from
the chuck (9).
3. Release the chuck (9).
Removing/attaching the
parallel guide
The parallel guide can be fitted on
both sides of the device.
Attaching the parallel guide
1. Loosen the retaining screws (11) if nec-
essary.
2. Slide the parallel guide (18) through
the slide-in openings (10).
3. Retighten the retaining screws (11).
Removing the parallel guide
1. Loosen the retaining screws (11).
2. Pull the parallel guide (18) out of the
slide-in openings (10).
Removing/attaching the
tension tear protection
Removing the tension tear protec-
tion
1. Press the tension tear protection (22)
away from the recess in the slide shoe
(21).
Attaching the tension tear protec-
tion
2. Press the tension tear protection (22)
into the recess in the slide shoe (21).
30
Operation
Switch off the device and re-
move the battery before car-
rying out any maintenance
work.
Ensure that the ambient tem-
perature does not exceed
50 °C or fall below -20 °C
during work.
Switching on and off
1. Push the battery (23) along the guide
rail into the device. You will hear it
click into place.
Switching on:
2. The rotary wheel (27) on the back of
the device has 6 levels for achieving
the desired speed.
3. To switch the device on, push the on/
off switch (1) forwards.
Switching off:
4. Pull the On/off switch (1) backwards to
switch off the device.
Adjusting the mitre
angle
1. Remove the Allen key (17) from the
storage area on the side of the device
housing.
2. Loosen the hexagon socket screws (6)
with the Allen key (17).
3. Set the bottom plate (4) to the desired
position (-45° to 45°). A total of 6 lev-
els can be set (-45°, -22.5°, 0°, 15°,
30° and 45°).
4. Tighten the hexagon socket screws (6)
with the Allen key (17).
5. Place the Allen key (17) back into the
storage area on the side of the device
housing