MAINTENANCE
MAINTENANCE REMINDERS
Maintenance reminder codes will be shown on the Data
Display based on unit Lifetime Hours. The maintenance
codes will be displayed until the unit is turned off. Refer to
the Maintenance section for specific procedures.
Maintenance Code Required Maintenace
P25
Change engine oil
P50
Change engine oil, clean air filter
P100
Change engine oil, clean air filter
Accidental start-up. Disconnect the spark plug boot from
the spark plug and disconnect the battery quick-connect
plugs when performing maintenance on the generator.
MAINTENANCE SCHEDULE
Regular maintenance will improve performance and
extend the service life of the generator. Follow the hourly
or calendar intervals, whichever occurs first. More frequent
service is required when operating in adverse conditions
as noted below.
Before Each Use
Check engine oil
After First 25 Hours or First Month
Change engine oil
After 50 Hours or Every 6 Months
Change engine oil
Clean air filter
After 100 Hours or Every 6 Months
Inspect/clean spark arrestor
Inspect/clean spark plug
Inspect/adjust valve clearance
After 300 Hours or Every Year
Replace spark plug
Replace air filter
Change oil every month when operating under heavy
1
load or in high temperatures.
Clean more often under dirty or dusty conditions.
2
Replace air filter if it cannot be adequately cleaned.
Recommend service to be performed by authorized
3
Westinghouse service dealer.
1
2
3
MAINTENANCE
MAINTENANCE REPLACEMENT PARTS
Description
Air filter
Oil drain plug crush washer
Spark arrestor
Battery, 14 AH
Spark plug
AIR FILTER MAINTENANCE
Fire hazard. Never use gasoline or other flammable
solvents to clean the air filter. Use only household
detergent soap to clean the air filter.
The air filter must be cleaned after every 50 hours of use or
six months (frequency should be increased if the generator
is operated in a dusty environment).
1. Place the generator on a level surface and allow the
engine to cool for several minutes.
2. Release the top and bottom clips then remove the air
filter cover.
3. Remove the air filters. Use compressed air to clean the
coarse air filter.
Note: The foam air filter element is oil soaked. Use an
appropriate cleaning container.
Avoid skin contact with engine oil. Wear protective
clothing and equipment. Wash all exposed skin with
soap and water.
4. Remove the foam air filter and wash it by submerging
the element in a solution of household detergent soap
and warm water. Slowly squeeze the foam to thoroughly
clean.
DO NOT twist or tear the foam air filter element during
cleaning or drying. Only apply slow but firm squeezing
action.
5. Rinse the air filter element by submerging it in fresh
Westinghouse Outdoor Power Equipment, LLC | 19
Part Number
5692
94004
6866
511012
97108
NOTICE
NOTICE