EdilKamin BERING PLUS Installation, Usage Et Maintenance page 25

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 44
FEATURES
The boiler is fuelled by pellets. These are little, cylindrical
L
shapes of pressed wood whose combustion is controlled elec-
tronically.
M
The fuel tank (A) is located at the rear of the boiler. Filling the
tank is through the back of the lid at the rear of the top.
The fuel (pellets) is taken from the tank (A) and, by means of a
screw (B) operated by a gear motor (C), is sent to the combus-
tion chamber (D).
H
The ignition of the pellet is via air heated by an electrical he-
A
ating element (E) and is sucked into the crucible by a smoke
extractor (F)
B
The combustion air is drawn into the room (where there must
be an air intake) smoke extractor (F).
The smoke produced by combustion, is extracted from the
thermo-stoves through the smoke extractor (F), and expelled
D
E
from the pipe union (G) located in the bottom portion of the
C
rear of the boiler.
The ash falls under and beside the crucible in which is housed
an ash tray from which the ash must be periodically removed
F
by vacuuming when cool.
The fi replace in steel, with cast iron base, is closed at the front
P
by a blind door.
The door has an inspection window to check on the fl ame.
G
The hot water produced by the boiler is transferred via a
circulator built into the boiler-stove itself, to the heating system
circuit.
I
The exchanger tubes are cleaned by means of tube-cleaners (H)
manoeuvred with a handle (L).
The entire boiler and door are insulated which makes it more
effi cient so that the water hot water produced by the boiler is
not dissipated in the place of installation but is conveyed only
to the hydraulic system.
The boiler is designed to function with closed expansion tank
(I) and pressure valve, both of which are built in.
A hydraulic kit (P) is positioned to the side, composed of: cir-
culator, safety valve, expansion tank.
Fuel quantity, smoke extraction/combustion air supply and
pump activation are regulated by the control board which is
®
equipped with Leonardo
software to achieve high combustion
effi ciency and low emissions.
It also has a two-pole socket to connect an external graphic
panel (optional) and/or the Domoklima (the Edilkamin inte-
grated control unit).
The synoptic panel (M) which allows managing and viewing
all the operating phases, is installed on the door.
A serial port is found at the back of the boliler (cable: code
640560) to be connected to devices that allow remote ignition
(e.g. remote telephone, local thermostat).
Operating modes
(for further details, please see page 34)
The temperature of the water required in the system is set via
the panel (standard recommendation 70° C) and the boiler
manually or automatically modulates the power to maintain or
reach this temperature.
The Eco function can be enabled in small systems (the boiler
shuts down and goes on again according to the water tempera-
ture required).
- 25
-

Publicité

Table des Matières
loading

Table des Matières