Pentair ETi 400 Instructions D'installation page 39

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ELECTRICAL CONNECTIONS
120 VAC Wiring
Connect the BLUE PLUG (120 VAC) into the 12-pin plug located on the electrical panel, see Figure 30).
Connect the L1 to the BLACK WIRE in the heater.
Connect the NEUTRAL WIRE to the RED WIRE in the heater.
Connect the GROUND WIRE to the GREEN WIRE in the heater.
240 VAC Wiring
Connect the RED PLUG (240 VAC) into the 12-pin plug located on the electrical panel, see Figure 30).
Connect the L1 to the BLACK WIRE in the heater and the other L2 to the RED WIRE at the heater.
Connect the GROUND WIRE to the GREEN WIRE in the heater.
Figure 31.
CAUTION! The 120 VAC (Blue plug)
voltage selector is NOT interchangable
with the MasterTemp
Heater voltage selector (Black plug)
Rev. C 4/2017
(CONTINUED)
Panel latch lock
Fireman Switch Board
®
or StaRite
®
ETi 400 High Efficiency Pool and Spa Heater Installation and User's Guide
Section 2: Installation Instructions
Figure 32.
120 VAC
(BLUE)
39
220 VAC
(RED)

Publicité

Table des Matières
loading