menu (parameters) can be accessed directly.
Here follows a list of the main menus and the respective submenus
available.
The predefined parameter is shown between square brackets [ 0 ].
The writing appearing on the display is indicated between round brackets.
Refer to Figures A and B for the control unit configuration procedure.
6.1) Parameter Menu (PARAM)
1 - Partial opening (m) (Part Open ) [010 %]
Set the numerical value for partial opening from 10cm/0.32ft (000%) to
6m/19.68ft (100%).
2 - Automatic Closing Time (TCA) (tca) [ 40s ]
Set the numerical value of the automatic closing time from 1 to 180
seconds.
3 - Encoder (Encoder) [ 80 ]
Set the encoder sensitivity value from 1 to 99. A higher value
corresponds to greater sensitivity, whereas a lower value corresponds
to lesser sensitivity.
WARNING: Check that the value for impact strength conforms
to the current standards. Incorrect sensitivity setting can cause
damage to persons, animals or things.
4 - Opening torque (open torque) [ 50% ]
Set the motor opening torque value between 1% and 99%.
5 - Closing torque (cls. torque) [ 50% ]
Set the motor closing torque value between 1% and 99%.
6 - Slow-down torque (slov torque) [ 50% ]
Set the motor opening and closing slow-down torque value between
1% and 99%.
7 - Brake (Brake) [ 0% ]
Set the required brake value between 0 and 99%, compatibly with the
weight of the gate and the existing stresses.
8 - Zone (zone) [ 0 ]
Set the zone number between a minimum value of 0 and a maximum
value of 127. See paragraph 7 on "Serial connection".
9 - Slow-down Distance (dist. slou) [ 000%]
Set the required slow-down distance for opening and closing between
20% and 100%. The 000% value does not carry out any slow-down.
NOTE: If a slow-down distance value other than 000% is set (min. 20%),
after the first manoeuvre, power failure, reset, or manual gate release, the
control panel carries out a complete manoeuvre at reduced speed, in order
to learn the length of gate stroke.
6.2) Logic Menu (logic. )
- TCA ( tca ) [ OFF ]
ON
Activates automatic closing
OFF Excludes automatic closing
- 3 Steps (3 step) [ OFF ]
ON
Enables 3-step logic. A start impulse has the following effects:
door closed: ............................................................................ opens
on opening: ............................ stops and enters TCA (if configured)
door open: .............................................................................. closes
on closing: ....................................... stops and reverses movement
after stopping: ......................................................................... opens
OFF Disables 3-step logic
- Opening Impulse lock (Ibl open) [ ON ]
ON
The Start impulse has no effect during the opening phase.
OFF The Start impulse becomes effective during the opening phase.
- Impulse lock TCA (ibl TCA ) [ OFF ]
ON
The Start impulse has no effect during the TCA dwell period.
OFF The Start impulse becomes effective during the TCA dwell period.
- Pre alarm (pre-alarM) [ OFF ]
ON
The blinker comes on about 3 seconds before the motor starts.
OFF The blinker comes on at the same time as the motor starts.
- Hold-to-run (hold-to-run ) [ OFF ]
ON
Hold-to-run operation: the manoeuvre continues as long as the
command key is kept pressed.
OFF Impulse operation: one impulse opens the gate if closed, and closes
it if open.
- Rapid closing (fast cls ) [ OFF ]
ON
Closes the gate after photocell disengagement, before waiting for
the end of the TCA (automatic closing time) set.
OFF Command not entered.
- Photocells on opening (photc. open) [ ON ]
ON:
In case of obscuring, this excludes photocell operation on opening.
During the closing phase, it immediately reverses the motion.
OFF: In case of obscuring, the photocells are active both on opening and
on closing. When a photocell is obscured on closing, it reverses the
motion only after the photocell is disengaged.
- Master/Slave (Master) [ OFF ]
ON
The control panel is set as Master in a centralised connection (see
Paragraph 7).
OFF The control panel is set as Slave in a centralised connection (see
Paragraph 7).
INSTALLATION MANUAL
- Loop (loop) [ OFF ]
ON
In the case of a closed loop centralised connection (Fig.5), set the
control unit to ON.
OFF In the case of an open centralised connection (Fig.5), set the control
unit to OFF.
Photocell test (test phot) [ OFF ]
-
ON
Activates photocell check (see fig. 7 to 14)
OFF Deactivates photocell check
Electric edge test (test bar) [ OFF ]
-
ON
Activates electric edge check (see fig. 7 to 14)
OFF Deactivates electric edge check
6.3) Radio Menu (radio)
-
Add (add)
Allows you to add one key of a radio control device to the receiver memory;
after storage it displays a message showing the transmitter number in the
memory location (from 01 to 64).
NOTE: When using transmitters with two or more channels, the first push-
button which has been stored is associated to the START function. If a
second push-button is stored, it will be associated to the partial open
function.
-
Read (read)
Checks one key of a receiver; if stored it displays a message showing the
receiver number in the memory location (from 01 to 64), and the key number
(T1, T2, T3 or T4).
Delete (erase 1)
-
Removes one single key of a transmitter from the receiver memory; after
deletion it displays a message showing the receiver number in the memory
location (from 01 to 64).
Eliminate list (erase 64)
-
WARNING! Completely removes all memorised radio control devices from
the receiver memory.
6.4) Language Menu (Language)
Allows you to set the language on the display programmer.
4 languages are available:
-
ITALIAN (TA)
-
FRENCH (FRA)
-
ENGLISH (ENG)
-
SPANISH (ESP)
6.5) DEFAULT MENU (default)
Restores the preset default values on the control unit.
6.6) Self-diagnosis Menu (selftest)
Allows you to carry out control unit self-diagnosis.
If, at the end of the diagnosis, the answer is OK, it means that the control
unit and connected devices operate correctly.
In case of error, the display indicates the number of the terminal which does
not operate correctly; thus proceed to checking the devices connected to
this, making reference to the following table:
22
Start error
23
Stop error
24
Photocell error
25
Opening limit-switch error
26
Closing limit-switch error
27
Partial open input error
28
Open error
29
Close error
30
Electric edge error
31
Clock error
6.7) Autoset Menu (Autoset)
Allows you to automatically set the following parameters:
Opening torque
Closing torque
Slow-down torque
Encoder
Brake
To carry out autosetting, connect two N.O. pushbuttons, if not provided, to
inputs 21-28 (Open) and 21-29 (Close).
WARNING!! The autoset operation is only to be carried out after checking
the exact leaf (opening/closing) movement, and correct limit-switch
activation.
Therefore, during display of the (.... .... ....) message, carry out about fifteen
opening and closing manoeuvres in "Hold-to-run" mode, by pressing and
keeping the OPEN or CLOSE pushbutton alternatively pressed until the
opening or closing limit switches are activated.
During this phase, the control panel carries out tests with various levels of
opening/closing torque, encoder sensitivity and brake value.
Moreover, during autosetting, the leaf may be stopped, due to the checks
which are being carried out by the control panel.
After this, if autosetting is successfully completed, the control unit
ENGLISH
13
LEO-MA UL - Ver. 01 -