Migatronic PI 350 Mode D'emploi page 15

Masquer les pouces Voir aussi pour PI 350:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
Special functions
2-times option for torch trigger
0: return to welding current by step. (default)
1: return to welding current by slope up
Press / Release
Press / Release
4-times option for torch trigger
Permit to define 6 different ways to control the
torch trigger when the machine is set as 4Times stroke (Lift
or HF). For detailed description of different behaviours see
the following diagrams. Select a value in the range 0...5
(1=default setting).
Press / Release
Press / Release
Press / Release
Keep
start current
Press / Release
Keep
start current
Press / Release
Keep
start current
Press / Release
Note: The start current is disabled in
slope-up period is set at 0.
Dynamic Oxide Control
0 = disabled
1 = enabled (default setting)
0
By STEP
1
By SlopeUP
Stop when key is released
Keep
final current
0
Stop when key is released
Stop when
slope completed
1
Stop when
slope completed
2
3
Stop when key is released
Stop when
slope completed
4
Stop when key is released
Keep
final current
5
,
and
if
3
4
5
Remote Control Option
Welding current can be controlled up to previous SET
or to MAX. External reference voltage can be 0-10V or 0-5V
(Condition 2 & 3 presents lower resolution)
0 = 0-10V  Imin to ISET (default)
1 = 0-10V  Imin to IMAX
2 = 0-5V
 Imin to ISET
3 = 0-5V
 Imin to IMAX
Torch Remote Control
Applies to software versions as of 2.17
Makes it possible to control how the control unit on the handle
is used when torch adjustment is enabled (
0 = Setting the current reference (factory default).
1 = Enabling/disabling TIG-A-Tack
(the TIG-A-Tack button is disabled).
The control unit is handled as follows:
Steps 1-3: TIG-A-Tack is enabled
Steps 4-7: The trigger is disabled
Steps 8-10: TIG-A-Tack is disabled
2 = Up/Down module
*
2A/
Enabling/Disabling
TIG-A-Tack
*
Keep pressed for constant increase/reduction
Learn more about TIG Ergo torches at http://migatronic.com
Saves all program settings in an SD card file. Insert an SD card in
the machine (same procedure as for SW update).
Loads program settings from SD card. Use P.SA. to save program
settings.
All the above settings will not be changed during reset to factory settings.
15
Trigger
Trigger
*
*
2A/
2A/
).
*
2A/

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pi 500

Table des Matières