General Remarks; Technical Characteristics - salmson SANITSON PREMIUM 204-0,6M Instructions De Montage Et De Mise En Service

Module de relevage domestique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH

1. GENERAL REMARKS

Installation and commissioning must only be performed by
qualified staff.
1.1 Application
The SANITSON PREMIUM lifting station is designed for lifting water from
buildings and ground below the sewer system. The SANITSON PRE-
MIUM may therefore be installed either indoors or outdoors.
WARNING! In accordance with standard EN 12056-1 regarding
"Indoor gravity drainage systems", depending on the type of pump,
it is compatible with valve water free from faecal matter (grey water),
valve water containing faecal matter from private dwellings, or rain-
water.
Depending on the type, the SANITSON Premium lifting stations are
compliant with standards 12050-1 or 12050-2 (see table 2).
Any materials/waste that may prevent the efficient operating of the
pump are prohibited (solids, fibrous materials, tar, sand, cement, ash,
bulky paper, debris, household waste, animal waste, fats, oils, etc.). If
valve water containing fats is produced, a grease-removal tank must
be used.
Always make sure that the indications given in the pump's installation
and commissioning manual are obeyed.
WARNING! During installation and commissioning, the current stan-
dards and specifications must be strictly observed.
TABLE 1
Total volume (L)
Installation height (mm)
Max authorised water table level from the
bottom of the tank (mm)
TABLE 2
TYPE
PUMP
SANITSON PREMIUM
MINI-SVO
204-0,6M
204-0,6M
SANITSON PREMIUM
MINI-SVO
204-0,5T4
204-0,5T4
SANITSON PREMIUM
FVO
204-0,7M/B EN-1
204-0,7MF
SANITSON PREMIUM
SVO
SVO 205-0,75M
205-0,75M
SANITSON PREMIUM
MINI-SVO
2-204-0,6M
204-0,6M
SANITSON PREMIUM
MINI-SVO
2-204-0,5T4
204-0,5T4
SANITSON PREMIUM
FVO
2-204-0,7M/B EN-1
204-0,7M
SANITSON PREMIUM
SVO
SVO 205-0,75M
205-0,75M
NF EN 12050-1 : Lifting stations for effluents containing or free from faecal matter.
(1)
NF EN 12050-2 : Lifting stations for effluents free from faecal matter.
(2)
When spare parts are ordered, all the information on the nameplate must be included on the order.
without extension
255
1000
500
Voltage
Power
Current
P1
(V)
(kW)
(A)
1-230V
1 x 0,94
4,5
3-400V
1 x 0,7
1,4
1-230V
1 x 1,0
4,4
1-230V
1 x 1,1
5,5
1-230V
2 x 0,94
2 x 4,5
3-400V
2 x 0,7
2 x 1,4
1-230V
2 x 1,0
2 x 4,4
1-230V
2 x 1,1
2 x 5,5

1.2 Technical characteristics

1.2.1 Description
Range
Pump type
Motor power P2
M = single-phase
T = three-phase
1.2.2 Connection and utility supplies
• Frequency : 50 Hz
• Effluent inlet coupling : ND100
• Ventilation duct coupling : Ø 75
• Maximum inlet flow rate : 15 % of the pump's flow rate at its opera-
ting point and 30% on double pump units.
• Maximum instantaneous load on the cover
(buried installation) : 200 kg (vehicles may not drive over and/or
park on the cover)
• Maximum pressure in the discharge duct : 4 bars
• Discharge duct connection (See FIG. 1 to 6)
• Raceway connection : Ø 63
SANITSON PREMIUM 1
with extension
325
1300
1000
Control
Level
unit
detection
temperature
without
Float
EC-DRAIN
switch
without
with
authorised
for 5 mins
YN 3212M
YN 3212T4
IPAE
(0-1mCE)
YN 3212M
YN 3212M
17
SANITSON PREMIUM-204-0,6 M
SANITSON PREMIUM 2
without extension
400
1000
500
Max.
Max.
Compliant
fluid
particle
with
size
standard
(°C)
(mm)
35
EN 12050-2
(2)
40
EN 12050-1
35°C
(1)
(60°C
44
max)
35
EN 12050-2
(2)
40
EN 12050-1
(1)
44
with extension
470
1300
500
Alarm
signal
Optional
available
Optional
available
Optional
available

Publicité