Spartherm PremiumEdition Série Notice De Montage page 84

Table des Matières

Publicité

HRS = heat recovery surface
C L AS SI C
S = Unit additionally tested with low power
Energy efficiency class
Nominal output
Heat output range
Efficiency
rec. chimney diameter
General data
Flue gas connection
Poss. Flue gas connection
Weight (approx.)
Rec. min. cross section for circ./incom. air (with WLM)
Rec. min. cross section for circ./incom. air (without WLM)
non-self-closing fire door (Design A)
self-closing fire door (Design A1)
Tests and values
Operation with open combustion chamber door
Level 2 BlmSchV
15a B-VG
Flue gas mass flow
Flue gas temp. (on flue gas connection)
Triple value for
Combustion air requirement
closed firebox
CO
2
Rec. diameter acc. to M-FeuVo
Combustion air requirement
Flue gas mass flow
Flue gas temperature (on the flue gas outlet)
Triple values for
req. supply pressure
chimney
CO
2
calculation
Fuel amount
Combustion air requirement
Distances – Heating
from wall
chamber
from floor
front
Radiant heat
side
area distance of pane
back
Install. floor
Insulation
Install. wall
(e
Side wall
xample mineral wool
Ceiling
mats acc. to AGI-132 Q)
Add.walling for wall protection
Install. floor
Install. wall
Heat insulation
(Example calcium
Side wall
silicate acc. to EN
Add.walling for wall protection
13501-2 ***)
as replacement for add. walling and insulation to mounting wall
as replacement for add. walling and insulation for side wall
Convection
Heat
Pane
distribution
H
O
2
back
Renova
above
Renova
Nova
C-44
B-Air
F-Air
side
Firewood
A+
A+
A+
kW
8.8
10.1
8.5
kW
6.2-11.4
7.1-13.1
6.0-11.1
%
>85
>85
>85
mm
180
180
160
mm
180
180
160
mm
145/150/160 145/150/160 145/150/180 145/150/180 145/150/180 145/150/180
kg
140
195
110
cm²
cm²
1060/1280
1580/1900
1170/1080
g/s
9.4
9.2
8.2
495
°C
357
355
142
HRS
Pa
12
12
12
%
7
8.1
7.7
cm
15
15
15
m³/h
34.7
34.1
30.3
g/s
25
26
20
°C
590
600
650
Pa
15
15
15
%
~ 9
~ 9
~ 9
kg/h
7
8
4
m³/h
68
77
41
cm
10
6
15
cm
22.8
16
23
mm
1000
1000
1000
mm
mm
cm
0
0
cm
11
11
13
cm
11
11
13
cm
17
17
19
cm
10
10
10
cm
0
-
0
cm
8
8
10
cm
8
8
10
cm
10
10
10
cm
9
9
11
cm
9
9
11
%
60
78
59
%
40
22
41
%
0
0
0
GB 41
Renova
Renova
Renova
Renova
C-44
Cs-42
Cs-42
Cs-50
Brown coal
Firewood
Brown coal
Firewood
A+
A+
A+
A+
7.8
6.5
6.5
7
5.5-10.1
4.6-8.5
4.6-8.5
4.9-9.1
>85
>85
>85
>85
160
160
160
160
160
160
160
160
150
110
105
105
107
1170/1080
990/1080
990/1080
990/1080
9.1
6.9
8.8
6.5
483
478
434
442
142
HRS
155
HRS
151
HRS
175
HRS
12
12
12
12
7.1
7.6
6.6
8.3
15
31.4
22.9
28
22.8
20
8.1
8.1
8.9
650
420
420
480
15
15
15
15
~ 9
~ 9
~ 9
~ 9
4
3.5
3.5
3.9
41
39
39
40
15
18
18
18
23
12.5
12.5
12.5
1000
1100
1100
1100
0
0
0
0
13
9
9
9
13
9
9
9
19
14
14
14
10
10
10
10
0
0
0
0
10
7
7
7
10
7
7
7
10
10
10
10
11
8
8
8
11
8
8
8
59
61
61
59
41
39
39
41
0
0
0
0
Please check the updated technical data on www.spartherm.com. Changes and errors excluded
GB
Renova
Nova E
Renova A
Cs-50
H ² O
H ² O
Brown coal
A+
A+
A+
14 |
13.4 |
7
9
6.9
4.9-9.1
9.8-18.2
9.4-17.4
>85
>85
>85
160
180
180
160
180
180
150
107
297
190
990/1080
990/990
1215/978
7.8
12.7
12.8
Abg. 193
408
362
Abg.
340
176
HRS
165
HRS
166
HRS
12
12
12
7.5
8.2
7.7
15
15
26.5
46.3
47.3
8.9
25
25
480
520
480
15
14
12
~ 9
~ 9
~ 9
3.9
10
8
40
103
82
18
6
6
12.5
19.8
18
1100
1000
700
0
0
0
9
9
12
9
9
12
14
9
9
10
10
10
0
0
0
7
7
9
7
7
9
10
10
10
8
8
10
8
8
10
59
14
26
41
22
23
0
64
51