Spartherm PremiumEdition Série Notice De Montage page 81

Table des Matières

Publicité

Energy efficiency class
Nominal output
Heat output range
Efficiency
rec. chimney diameter
General data
Flue gas connection
Poss. Flue gas connection
Weight (approx.)
Rec. min. cross section for circ./incom. air (with WLM)
Rec. min. cross section for circ./incom. air (without WLM) cm²
non-self-closing fire door (Design A)
self-closing fire door (Design A1)
Tests and values
Operation with open combustion chamber door
Level 2 BlmSchV
15a B-VG
Flue gas mass flow
Flue gas temp. (on flue gas connection)
Triple value for open
Flue gas temp. downstream of HRS
firebox
Combustion air requirement
req. supply pressure
Flue gas mass flow
Flue gas temperature (on flue gas connection)
Triple value for
Rec. supply pressure
closed firebox
CO
2
Rec. diameter acc. to M-FeuVo
Combustion air requirement
Distances – Heating
from wall
chamber
from floor
front
Radiant heat
area
side
distance
back
Install. floor
Insulation
Install. wall
(example mineral
Side wall
wool mats acc. to
Ceiling
AGI-132 Q)
Add.walling for wall protection
Install. floor
Replacement
Install. wall
insulation mat.
Side wall
Calcium silicate
Ceiling
Convection
Heat
Pane
distribution
H
O
2
* only complies with15a 2015 w. AT att., attention: Flue gas conn. height + 160 mm
NSHF = heat recovery surface
behind
Varia
1V H
O XL
²
Export
A+
12 |
kW
8.5
kW
8.4-15.6
%
>80
mm
200
mm
200
mm
180
kg
341
cm²
800/1000
g/s
°C
°C
m³/h
Pa
g/s
10.8
°C
235
Pa
12
%
9.1
cm
15
m³/h
38
cm
6
cm
mm
1500
mm
mm
cm
0
cm
6
cm
6
cm
cm
10
cm
0
cm
5
cm
5
cm
%
11
%
18
%
71
H
O
S = Unit additionally tested with low power
2
Varia
Varia
Varia
Varia
1V H ² O
1V H
O XXL
1Vh H
O
1Vh H
²
²
XXL
Export
Export
A+
A+
A+
A+
15 |
21 |
8 |
11 |
11
15
5
10.5-19.5
14.7-21.2
5.6-10.4
7.7-14.3
>85
>85
>80
>80
200
200
180
180
200
200
180
180
180
180
351
351
374
374
800/1000
800/1000
800/1000
800/1000
13.1
14.8
6.7
10.4
225
240
240
250
12
12
12
12
8.9
10.9
9.6
8.6
15
15
15
15
48.2
55
24
37
6
6
6
6
1500
1500
1500
1500
0
0
0
0
6
6
6
6
6
6
6
6
10
10
10
10
0
0
0
0
5
5
5
5
5
5
5
5
9
11
2
10
18
18
35
35
73
71
63
55
*** Example SILCA 250KM: approved replacement insulation mat.
GB 38
acc. to DIBt No. Z-43.14-117 and CE 0432-CPD-420002242/2-6
Varia
Varia
Varia
O
1Vh H ² O XL
1Vh H ² O XL
1Vh H
O XXL
²
²
Export
A+
A+
A+
9 |
12 |
15 |
6
6
8.5
11
6.3-11.7
8.4-15.6
10.5-19.5
>85
>80
>85
200
200
200
200
200
200
180
180
180
379
379
389
800/1000
800/1000
800/1000
7.5
10.8
13.1
220
235
225
12
12
12
9.7
9.1
8.9
15
15
15
26.3
38
48.2
6
6
6
1500
1500
1500
0
0
0
6
6
6
6
6
6
10
10
10
0
0
0
5
5
5
5
5
5
15
11
9
18
18
18
67
71
73
Varia
Varia
1Vh H
O XXL
Ah H ² O
²
Export
A+
A+
21 |
10.4 |
15
7.2
14.7-21.2
7.3-13.5
>85
>85
200
200
200
200
180
180
389
471
800/1000
250/300
14.8
8
240
230
12
12
10.9
11.1
15
15
55
26.5
6
6
1500
800
0
0
6
5
6
5
10
10
0
0
5
4
5
4
11
15
18
16
71
69

Publicité

Table des Matières
loading

Table des Matières