5.
SETTINGS
5.1 Trimmer
Output
TC
Automatic closing time. From 0 to 120 s, with TC<MAX.
With TC=MAX automatic closing is disabled.
The count starts with door stopped for time set with TC.
120 s
After the intervention of a safety (1-8), the countdown begins with the open door and lasts for the whole
time set with TC.
MIN=0 s
MAX=disabled
With TC=MAX or contact 1-9 open, automatic closing is disabled.
If disabled with 1-9, automatic closing is re-enabled, once the contact 1-9 has been closed again, only
after a control 1-5 or a remote control.
R1
Obstacle thrust adjustment. The control panel is equipped with a safety device that stops the opening
operation and stops and inverts the closing operation in the presence of an obstacle.
With R1=MIN there is maximum obstacle sensitivity (minimum thrust).
MIN
MAX=disabled
With R1=MAX the detection function is deactivated (maximum thrust).

5.2 Dip-Switches

Description
DIP1 Control 1-5 function.
DIP2 Selection of direction.
DIP3 Disengagement on the closing
stop with JR2=ON
Disengagement on the closing
stop with JR2=OFF
DIP4 State of door at start.
Indicates how the electronic panel
considers the door at the time of
start.
DIP5 Electric lock release.
DIP6 Pre-flashing light.
5.3 Jumpers
Description
SO Safety operation.
JR2 Automation type.
JR3 Maximum limit manoeuvering
forces.
JR4 Built-in radio receiver.
5.4 Signals
LED
POWER ALARM
24 V= power supply.
SA
Indicates that at least one of the N.C. safety contacts
is open.
SIG
During radio transmitter enabling/storing phase.
OFF
Step by step.
Opening towards gearmotor.
2 mm
5 mm
Open.
With DIP1=OFF the first control 1-5 closes
the door.
With DIP1=ON the first control 1-5 opens
the door.
Disabled.
Disabled during opening.
Enabled only with automatic closure with
TC>3 s.
OFF
The opening of contact 1-8 with door stopped
enables opening manoeuvre. In the last 30
mm before closing stop, this causes stop.
Up and over door with counterweight.
Normal closing force.
Disabled.
ON
23
Description
Opening.
Closing towards gearmotor.
0,5 mm
Note: use this selection to prevent an incom-
plete closing of the sectional doors.
5 mm
Close.
The first control 1-5 opens the door.
Note: automatic closing cannot be the first
control even if enabled.
Enabled.
Before opening from closed door, a thrust
is included in closing to facilitate electric
lock release.
Enabled for both opening and closing.
The opening of contact 1-8 with door
stopped prevents any operation.
Sectional and up and over door with
springs.
Reduced closing force.
Enabled.
Flashing
Encoder / automation fault.
Upon starting the LED flashes indicating the count of
the operations which have been carried out:
each quick flashing = 1000 operations
each slow flashing = 10000 operations
During radio transmission reception.
GB
ON
ON