Installing backguard (optional) __________________________________________________ GAS CONVERSION _____________________________________________________________ INSTALLATION CHECKLIST ______________________________________________________ FINAL PREPARATION ___________________________________________________________ BERTAZZONI SERVICE _________________________________________________________ ________________________________________________________________________ WARNINGS ____________________________________________________________________ WORKTOP AND KNOBS LAYOUT _________________________________________________ GAS COOKTOP ________________________________________________________________ ELECTRIC GRIDDLE ____________________________________________________________ KEEPING YOUR BERTAZZONI CLEAN _____________________________________________ TROUBLESHOOTING ___________________________________________________________ TWO YEARS LIMITED WARRANTY ________________________________________________...
/ Warnings WARNINGS To ensure proper and safe operation, the applian- WARNING! ce must be properly installed and grounded by a If the information in these instructions is qualifi ed technician. DO NOT attempt to adjust, not followed exactly, a fi re or explosion may repair, service, or replace any part of your ap- result causing property damage, personal pliance unless it is specifi...
Page 5
/ Warnings WARNING: Cancer and Reproductiv Harm- www.P65Warnings.ca.gov...
/ Data rating label / Before installation All opening and holes in the wall and fl oor, back DATA RATING LABEL and under the appliance shall be sealed before installation of the appliance. The data rating label shows the model and serial number of the rangetop.
For best removal of smoke and odors, the have been designed to work in conjunction with lower edge of the hood should be installed the Bertazzoni range and have the same fi nish for between 25 1/2” (65 cm) and 31 1/2” (80 cm) a perfect look.
/ Clearence dimensions CLEARENCES DIMENSIONS Installation adjacent to kitchen cabinets Metal hood This range may be installed directly adjacent to existing countertop high cabinets (36” or 91.5 cm min 25” 1/2 (65 cm) from the fl oor). For the best look, the worktop should be level with min 12”...
/ Installation requirements / Electrical connection INSTALLATION REQUIREMENTS ELECTRICAL CONNECTION Warning! ELECTRICAL ELECTRICAL SHOCK HAZARD A properly-grounded horizontally- mounted electri- Disconnect electrical power at the circuit bre- cal receptacle should be installed no higher than aker box or fuse box before installing the ap- 27”...
/ Wiring diagram WIRING DIAGRAM The electric wiring diagrams and schematics are attached behind the rangetop, and should not be removed except by a service technician, then replaced after service.
/ Gas connection GAS CONNECTION Warning! FLEXIBLE CONNECTIONS DO NOT USE AN OPEN FLAME WHEN In case of installation with fl exible couplings and/ CHECKING FOR LEAKS! or quick-disconnect fi ttings, the installer must use a heavy-duty, AGA design-certifi ed commercial fl...
/ Gas connection PRESSURE REGULATOR Since service pressure may fl uctuate with local demand, every gas cooking appliance must be equipped with a pressure regulator on the inco- ming service line for safe and effi cient operation. The pressure regulator shipped with the applian- ce has two female threads ½”...
/ Installation INSTALLATION APPLIANCE INSTALLATION Unpacking the rangetop • Remove all packing materials from the shipping pallet but leave the adhesive-backed foam layer over brushed-metal surfaces to protect it from scratches until the range is installed in its fi nalposition. Only the fi lm on the side panels should be removed before inserting the rangetop between the cabinets.
/ Installation INSTALLING THE ISLAND TRIM INSTALLING BACKGUARD (OPTIONAL) The island trim is only placed on the cooktop, re- The backguard is an optional contact you dealer move all tape and packaging before installing it. for buying it.
Save the nozzles removed from the rangetop for Replace nozzles using the conversion set sup- future use. plied with the rangetop or by a Bertazzoni authori- zed parts warehouse. Each nozzle has a number Step 1: pressure regulator indicating its fl ow diameter printed on the body.
Page 17
/ Gas conversion Step 4: minimum fl ame adjustment WARNING! These adjustments should be made only for use of the appliance with natural gas. For use with li- quid propane gas, the choke screw must be fully turned in a clockwise direction. SURFACE BURNERS Light one burner at a time and set the knob to the MINIMUM position (small fl...
/ Installation checklist / fi nal preparation / Bertazzoni service INSTALLATION CHECKLIST FINAL PREPARATION A qualifi ed installer should carry out the following • Before using the rangetop, remove any checks: protective wrap from the stainless steel. • All stainless steel body parts should be wiped...
/User Wrarning WARNINGS Warning and Important Safety Instructions ap- of the gas shut-off valve and how to shut it off in pearing in this manual are not meant to cover all an emergency. possible conditions and situations that may occur. Common sense, caution, and care must be exer- A certifi...
/ Warnings Recommended Utensils Cooking Safety • Use pans with fl at bottoms and handles • Once the unit has been installed as outlined that are easily grasped and stay cool. Avoid in the Installation Instructions, it is important using unstable, warped, easily tipped or that the fresh air supply is not obstructed.
/ Worktop and knobs layout WARNINGS WORKTOP AND KNOBS LAYOUT Room ventilation Heating element An exhaust fan may be used with the appliance; Left front burner in each case it shall be installed in conformity Left rear burner with the appropriate national and local standards. Exhaust hood operation may aff...
/ Bertazzoni service GAS COOKTOP BURNER CAPS AND GRATES The correct fl ame height depends on: • size and material of pan being used The burners and the burner caps must be proper- • food being cooked ly placed for the cooktop to function properly.
/ Gas cooktop USING THE POWER BURNER GAS SHUT-OFF SAFETY - THERMOCOUPLE To give further fl exibility, the dual power burner can be used as a single simmer burner if the cen- A fl ame failure device (thermocouple) on each tral burner alone is ignited or as a power burner if burner acts as a safety gas cut-off...
/ Electric griddle ELECTRIC GRIDDLE Available on 48’’ models only the griddle using a heavy cloth. • Turn the control knob to a maximum setting. The electric stainless steel griddle is manufactu- • Turn the heat off when the oil begins to smoke. red from 3/16 inches stainless steel designed for Allow the griddle to cool.
/ Keeping your Bertazzoni clean KEEPING YOUR BERTAZZONI CLEAN Burn hazard Make sure the heating elements are turned off and allowed to cool completely before any clea- ning and/or maintenance operation. Things to avoid: • Do not use a steam cleaner to clean the rangetop: the steam could reach electrical components and cause a short.
Here are answer to common problems you may experience. You are also welcome to call our toll free Customer Service line to trouble- shoot any issue with your Bertazzoni: ENGLISH 866 905 0010 if located in the US, BC, B, Sk and MB...
Defects and damage arising from external forces porcelain, with the exclusion of slight diff erences beyond the control of Bertazzoni SpA such as fi re, in color due to materials and painting/enamelling fl ood, earthquakes and other acts of God.