1
Figure 2: Schematic diagram of installation
1.
Sauna heater
2.
Control panel
3.
Sensor
4.
External on/off switch (option, door contact needed for func-
tion)
5.
Door contact (option)
Positioning the heater - normal installation
DANGER! No more than one heater may be instal-
led in the same sauna cabin.
Position the sauna heater:
•
on the same wall as the door (or the side wall if very close
to the door wall). The heater may also be placed in a recess
(see Figure 5).
•
Position the heater at a safe distance from the fl oor, side
walls and interior fi ttings (see Figure 3).
Position the sensor according the picture (see Figure 3).
1
4
3
Figure 3: Positioning the heater - normal installation
1.
Minimum distance from side wall: 110 mm
2.
Sensor position alt 1: 300 mm from heater
3.
Sensor
4.
Sensor position alt 2: 300 mm from heater front
5.
Sensor position: 150 mm from ceiling
6.
Minimum distance from ceiling: 1030 mm
7.
Minimum distance from interior fi ttings: 100 mm
8.
Minimum ceiling height: 1900 mm
9.
Minimum distance: 20 mm
10. Minimum distance from interior fi ttings: 30 mm
11. Distance from fl oor: 100-270 mm (with legs: 100 mm)
3
4
5
2
5
2
3
6
7
8
10
9
11
If the wall on which the sensor is to be installed is made of highly
heat-absorbing material (e.g. concrete, brick, etc.), or of hardened
glass, the sensor may be installed in the ceiling at a distance from
the heater, according to Figure 4.
1
1
Figure 4: Sensor installation on ceiling on centreline of heater as
seen from the front and side
1.
300 mm
Positioning the heater - recess installation
To position the sauna heater in a recess:
1.
Position the heater at a safe distance from the fl oor, side
walls and interior fi ttings (see Figure 5).
2.
Position the sensor according the picture (see Figure 5).
2
1
1
5
3
Figure 5: Positioning the heater - recess installation
1.
Minimum distance from side wall: 110 mm
2.
Sensor position alt 1: 300 mm from heater
3.
Sensor
4.
Max. 1000 mm
5.
Sensor position alt 2: 300 mm from heater front
6.
Sensor position: 150 mm from ceiling
7.
Minimum distance from ceiling: 1030 mm
8.
Minimum distance from interior fi ttings: 100 mm
9.
Minimum ceiling height: 1900 mm
10. Minimum distance: 20 mm
11. Minimum distance from interior fi ttings: 30 mm
12. Distance from fl oor: 100-270 mm (with legs: 100 mm)
6
3
7
8
4
9
11
10
12
11