10. Technical Data - ASO Safety Solutions SK 41 Manuel D'utilisation

Masquer les pouces Voir aussi pour SK 41:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

SK 41 Safety relay

10. Technical data

Supply voltage
Mains voltage
Low voltage:
Power consumption
P
= 3 VA
Mains_ax
P
= 1,5 W
E_max
Compliance
Category 3 in accordance with EN 954-1
Safety equipment in accordance with
EN 12978
Terminal resistance
safety contact edges
R
= 8,2 kΩ
A
R
> 11,5 kΩ
AO
R
< 25,5 kΩ
AU
Relay switching contact stages
max. switching voltage
max. switching current
Electrical service life
10
switching cycles at nominal load
5
Safety relay cycle times
Response time
Rest time
22
U
230 V AC 50/60Hz
Mains
U
24V AC/DC ±10%
E
230 V AC (or 115 V)
24 V AC/DC
upper switching valuet
lower switching value
250 V ~ / 30 V -
4 A ~ / 4 A -
< 13 ms
approx. 1 s
Certificate No.: 78/780/551696
08/205/B1-YMA127612
78/205/329916
44/205/06/336556
08/205/B1-127612a-d
Alarm relay switching times
Response time
Activation time
The alarm relay of the RLU Version switches
synchronous to the sensing device's actuation.
Housing
Polyamide PA 6.6
Self-extinguishing in accordance
with UL 94-V2
Dimensions (HxWxD) 99 x 22.5 x 114 mm
Protection class
Weight
Temperature range
Connecting cable diameters
0,75-1,5 mm
2
­
Test report No.: 04/YTT551696
01/YMA127612
06/YTT/329916
06/YMA336556
01/YMA127612
0.5 s
3 s
IP20
210 g
-20°C to +55°C
single-wire or
flexible­conductor­

Publicité

Table des Matières
loading

Table des Matières