13. Technical specifications
Supply voltage
Power consumption
Certifications
Category 3 acc. to EN 954‑1
Safety device acc. to EN 12978
Terminal resistance of the SCEs
nominal value
upper switching point
lower switching point
Relay stages
Max. switching voltage
Max. switching current
Mechanical life‑time
Safety relay switching times
Response time
Turn‑off time
Assembly
Plug base for 35 mm DIN snap‑on rail mounting
Housing
11‑pin DIN plug‑base housing with plug base for 35 mm
mounting rail (DIN rail)
Dimensions: (HxWxD)
Housing
Housing incl. plug base
Protection class
Weight
Temperature range
Connection cable cross-section
single- or fine-stranded cable 0,75-1,5 mm
All voltages connected to the switching unit must be
safely isolated!
20
U
24 V AC/DC A10%
E
P
3 VA
max
R
= 8,2 kΩ
nom
R
> 20 kΩ
AO
R
< 2,5 kΩ
AU
30 V ~ / 30 V ‑
5 A ~ / 5 A ‑
>10
actuations
6
<
20 ms
> 500 ms
82 x 38 x 84 mm
82 x 38 x 110 mm
IP20
225 g
‑25°C to +55°C
2
Certificate no.:
78/780/551696
Test report no.:
04/YTT551696