Displays; Alarms - Dal Zotto INSERTO 700 2.0 Manuel Utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

DISPLAY
OFF
START
PELLET FEEDING
IGNITION
START UP
WORK
MODULATION
BURN POT CLEANING
FINAL CLEANING
STAND BY
EXT STAND BY
COOLING STAND BY
COOLING STAND BY
BLACK OUT
LOW
HOT
1
PELLETS
LOW
1
1
1
DISPLAY
1
66
Stove o
The start phase is in progress
Pellet feeding during the ignition phase is in progress
The ignition phase is in progress
The start phase is in progress
The normal work phase is in progress
The stove is modulating
The automatic burn pot cleaning is in progress.
When the stove is switched-o , nal cleaning is in progress. The nal cleaning phase lasts about 10
minutes.
Stove o due to temperature reached and in stand-by for re-ignition.
Stove o due to an external thermostat, in stand-by for re-ignition
A new ignition is attempted when the stove has just been switched o . When the stove switches o , one
must wait for the complete shutdown of the fumes motor, then clean the burn pot.
The stove can only be re-ignited when these operations have been performed.
The stove is cooling due to black out
Room thermostat set at minimum value.
In this mode the stove only works at 1st power independently from the power set. To exit this function
just raise the room temperature using button 4 and then key 2.
Room thermostat set at maximum value.
The stove works at the set speed, without ever modulating. To exit this function just lower the set
temperature using button 4 and then key 1.
The "PELLETS LOW" message combined with key 1 ashing slowly indicates that the pellets tank is at
minimum.
With the machine switched o and fully cooled down, load the pellets tank.
EXPLANATION
The xed triangle on the display and
key 1 ashing slowly indicate the
presence of an alarm.

DISPLAYS

REASON

ALARMS

On and ashing: indicates the presence of an alarm
The alarm can be reset by pressing button 3 for 3 seconds only if
the fumes motor has stopped and if 15 minutes have elapsed from
when the alarm was displayed.
ENGLISH
SOLUTION

Publicité

Table des Matières
loading

Table des Matières