GENERAL MENU

1
2
3
SET CLOCK
2
*ENABLE CHRONO
2
CHRONO SETTING
2
LANGUAGE
2
USER
2
TECHNIC SET
QUALIFIED TECHNICIAN USE
ONLY
*Where present

GENERAL WARNINGS

Advice to follow for the rst start-ups of the product:
During the rst hours of operation, there may be some smoke or
odours, but they are due to the normal "thermal break-in" process.
During this process, the duration of which changes depending on
the product, it is recommended to:
Š Ventilate the room well
Š If present, remove any majolica parts from the top of the
product
Š Activate the product at the maximum power and temperature
Š Avoid remaining in the room for a long time
Š Do not touch the surfaces of the product
Notes:
The process is completed after a few heating/cooling cycles.
Do not use for the combustion of elements or substances other than
those indicated in the manual.
IT IS FORBIDDEN TO USE THE APPLIANCE WITHOUT THE DIVIDER AND/
OR GLASS PROTECTION SEE THE FIGURE TO THE SIDE .
ITS REMOVAL JEOPARDISES THE SAFETY OF THE PRODUCT AND
IMMEDIATELY VOIDS THE WARRANTY PERIOD.
IN THE EVENT OF WEAR OR DETERIORATION CONTACT THE ASSISTANCE
SERVICE TO REPLACE THE PART
THE REPLACEMENT IS NOT COVERED BY THE PRODUCT WARRANTY
AS IT IS A PART SUBJECT TO WEAR .
52
OFF
22.5°C
14:10
4
5
6
6
ENABLE CHRONO
6
PROG. 1 - 2 - 3 - 4
ON/OFF
6
6
IT,EN,FR,DE,ES,PT
6
1
GO BACK EXIT
3
2
PARAMETER SCROLLING: NEXT 2 ; PREVIOUS 3
6
4
5
MODIFY SETTINGS DATA: INCREASE 4 ; DECREASE 5
6
CONFIRM ACCESS MENU
CONFIRM
WITH KEY 6
DISPLAY
2
PELLETS
IN %
2
V1 AIR
TANGENTIAL
2
STAND BY
2
KEYS LOCKED
2
**V2 AIR
DUCTING
2
RESET
Before turning on the product, it is necessary to perform the
following checks:
Š If it is intended to be connected to a hydraulic system, it must
be complete and fully functional and in compliance with the
instructions given in the product manual and with the relevant
regulations in force.
Š The pellet hopper must be completed loaded
Š The combustion chamber and the burn pot must be clean
Š Make sure that the re holder, the ash pan and the pellet
hopper close hermetically (if present in the hermetic version); they
must be closed and there must be no foreign bodies in the sealing
elements and gaskets.
Š Check that the power cord is properly connected
Š The bipolar switch (if present) must be set to position "1".
ENGLISH
2
START PRG1
2
2
STOP PRG1
2
2
MONDAY PRG1...
ON OFF
2
2
...SUNDAY PRG1
ON OFF
2
2
SET PRG1
07°C
2
REPEAT THE SAME STEPS FOR
THE OTHER 3 TIME SLOTS
GLASS PROTECTION
DAY
HOURS
MINUTES
DATE
MONTH
YEAR
**
NOT USED
BURN POT DIVIDER