Assign free outputs
(according to
diagram)
Brief description
Code to enter the menu. The other menu items are only displayed once the correct
CODE
code has been entered.
Version number
VER
Selection of the program number
PR
Linking of outputs (A1 with A2, A1 with A3 or A2 with A3). The speed control (only
LO
output 1) can be assigned within the program diagram in any way desired by this
means.
Priority assignment (this menu item is only displayed for program diagrams with
PA
priority)
Maximum limit - switch-off threshold (3 times)
max
Maximum limit - switch-on threshold (3 times)
max
Minimum limit - switch-on threshold (3 times)
min
Minimum limit - switch-off threshold (3 times
min
Difference - switch-on threshold (3 times)
diff
Difference - switch-off threshold (3 times
diff
The number of minimum thresholds, maximum thresholds, and differences is displayed according to
the program selected.
E.g. 16.34
Time
Sets the date (timestamps for data lines) and automatic / manual settings between
DATE
summer and normal time.
Time window (available 3 times)
TIME W
Timer function
TIMER
Assignment of unused outputs
A3 A1
Output in automatic or manual mode (ON/OFF) This menu is available for every
O AUTO
output.
Control output in automatic or manual mode. In manual mode the controller is switched
C AUTO
from 10V to 0V (ON/OFF). This menu is available for every control output.
Automatic / manual
mode (3 times) for
outputs 1 – 3
Automatic / manual
mode (2 times) for
the control outputs
English
23