5.2.1 Activating the lock function
1) First recall the frequency adjusting mode:
Keep the key SET (7) pressed for 2 s.
2) As soon as the indication MHZ flashes in the
display, shortly press the key SET to change
into the lock mode:
play (locking deactivated).
3) Press the key
(5):
play.
4) Memorize the adjustment by pressing the
key SET.
is shortly displayed, the ad-
justing mode is exited, the unit returns to nor-
mal operation.
5.2.2 Deactivating the lock function
1) The power switch (2) must be set to ON.
2) Keep the key SET (7) pressed for 3 s until
flashes in the display.
3) Press the key
(6):
display.
4) Memorize the adjustment by pressing the
key SET.
is shortly displayed, the ad-
justing mode is exited, the unit returns to nor-
mal operation.
All rights reserved by MONACOR
may be reproduced in any form or by any means for any commercial use.
flashes in the dis-
flashes in the dis-
flashes in the
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual
6 Specifications
Type of unit: . . . . . . . . . PLL multifrequency
Radio frequency range: 863.125 – 864.875 MHz
Audio frequency range: 40 – 18 000 Hz
Frequency stability: . . . ±0.005%
Transmitting power: . . . < 10 mW (EIRP)
Ambient temperature: . 0 – 40 °C
Power supply: . . . . . . . two 1.5 V batteries of
Dimensions: . . . . . . . . . 78 × 190 × 34 mm
Weight: . . . . . . . . . . . . 160 g
Connection: . . . . . . . . . mini XLR
1 = ground
2 = signal input
1
3
3 = operating voltage 5 V for
2
the microphone
Subject to technical change.
pocket transmitter
size AA (R6)
GB