4.6.4 Menu 04 – select language
With this selection it is possible to select the dialogue language
from those available entered in the menu, and namely:
-
ITALIAN
-
FRENCH
-
ENGLISH
-
GERMAN
-
SPANISH
4.6.5 Menu 05 – standby mode
By selecting ON in STANDBY mode the corresponding symbol on the display lights up and the stove shuts down
automatically when the room temperature T has reached the set value (Tset + ΔT) for a given time.
The next restart in automatic will be possible only when the room temperature falls below the set value by a few
degrees and precisely (Tset - ΔT) where ΔT default = 2°C.
With the OFF selection, the modulation function is active but not the STANDBY mode. Therefore when the
temperature exceeds the set value the stove will operate at minimum power.
If the installation involves the use of a hot water tank, the standby mode is restricted to ON, and cannot be disabled.
4.6.6 Menu 06 – buzzer
With this selection it is possible to activate/deactivate stove acoustic signalling.
4.6.7 Menu 07 – initial loading
The setting of LOAD INITIAL allows pellet preloading for a time equal to 90 sec. with the stove off or cold. It is
started with the button P1 and stopped with the button P4.
Button 'P1'
4.6.8 Menu 08 – stove status
With this selection it is possible to display the instantaneous stove status giving the operating status of the various
devices connected to it; various pages placed in succession are available for monitoring.
4.6.9 Menu 09 – settings by technician
This selection is reserved for the authorised technician of the COLA service centre.
Modification of the technical parameters of menu 09 must be done by authorised and competent
personnel; any changes made at random can cause serious damage for which COLA declines any
liability.
4.7 Remote control
The remote control works with the settings made in the control panel and allows stove lighting-shutdown, and
adjustment of the required output and temperature.
Since this device transmits through an infrared diode, it must be pointed at the receiver unit in the control panel.