1. Travel limit setting Opening & closing force self-learning
2. Matching the receiver and transmitter
Fig. A
Fig. B
EN ::: 10
Press 'SET' button and hold on until the LED displays
figure '1', then adjust the up limit by pressing 'UP'
button. Fine-tuning 'UP' or 'DOWN' button to de-
termine the final up limit position then press 'SET'
button the display turn into '2' automatically.
Adjust the down limit by pressing 'DOWN' button.
Fine-tuning 'UP' or 'DOWN' button to determine
the final down limit position then press 'SET' button.
The opener will operate a cycle automatically to
remember the limit positions and the opening &
closing force.
Press 'CODE' button and hold on until the LED dot
is on. (Fig. A) Then press any button on the transmit-
ter once, the dot will be off; press the button again
the dot will fast flash then LED displays '11' (Fig. B).
After that the transmitter will be available.
Press 'CODE' button more than 8 seconds until the
LED displays 'C', all the stored codes will be dele-
ted.