Mesto PICO Mode D'emploi page 15

Masquer les pouces Voir aussi pour PICO:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
GB
IRL
2. Activate the shut-off valve [7] (Fig. 12)
Spraying may now begin.
3. Make certain the optimum spraying pressure is set (→ Table 2) on the piston pressure
gauge [14] (Fig. 10).
Spraying pressure
1.5 bar
2.0 bar
3.0 bar
Table 2. Dependence: spraying rate and spraying pressure
4. If the spraying pressure decreases more than 0.5 bar from the optimum level, pump
some more.
If liquid mixed with air emerges from the nozzle, the tank is empty.
After Usage
Observe the instructions in the section entitled "Safety".
1. Pull up the red piston pressure gauge handle [14] until the tank is depressurized. (Fig. 4)
2. Lock the piston rod with handle [16].
3. Unscrew the pump [2] from the tank. (Fig. 6)
4. Dilute the remaining quantity twice in a row with 1/2 liter of water each time and spray
the resulting liquid onto the treated area.
Collect and dispose of the residual liquid according to all applicable laws,
requirements and regulations. Observe the instructions of the spray product
manufacturer!
5. Wipe off the spraying device with a moist cloth. (Fig. 14)
6. For drying and storing the device, keep the tank [1] and pump [2] separate in a dry place
protected from sunlight and freezing temperatures (Fig. 14)
Clean the protective equipment and yourself every time after usage.
Care and maintenance
Observe the instructions in the section entitled "Safety".
After using the device 50 times or at least once a year:
• Unscrew the pump [2] from the tank. (Fig. 6)
• Dismantle the pump [2].
a) Unlock the piston rod with handle [16].
b) Pull the piston rod with handle [16] out of the cylinder tube up to the stop and turn it
counterclockwise (Fig. 13)
c) Disconnect the piston rod with handle [16] and the cylinder tube [2]. (Fig. 13)
• Grease the diaphragm [18]. (Fig. 15)
• Assemble the pump.
a) Push the piston rod with handle [16] into the cylinder tube. (Fig. 16)
b) Hold the cylinder tube [2] and strongly press in the guiding plug [19] with your thumb.
(Fig. 16)
c) Pull the piston rod with handle [16] up to the stop down and turn it clockwise (Fig. 16)
The guiding plug [19] snaps in.
AUS
USA
Spray quantity for hollow cone nozzle
0.49 l/min (0.13 gal/min)
0.56 l/min (0.15 gal/min)
0.69 l/min (0.18 gal/min)
15
NZ
CDN
IND

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Herbi32323232u

Table des Matières