1. Switch:
2-times
symbol
Start welding by pressing the trigger on the
torch. Welding continues until the trigger is
released.
Spot
symbol
The switch is set at Spot. When the trigger on
the torch is pressed, welding starts. Welding
stops automatically, depending on the time set
on control 4 (0.15-2.5 secs.)
Stitch
symbol
The switch is set at Stitch. When the trigger is
pressed, welding starts. The welding automati-
cally stops, depending on the time set on control
4. After an interval fixed at control 5 the same
cycle continues automatically and only ceases
when the trigger on the torch is released.
4-times
symbol
Welding starts the first time the trigger is
pressed (after which the trigger can be re-
leased) and continues until the trigger is
pressed again to stop the welding process.
2. ON
Lights when the machine has been turned on.
3. Overheating
Lights if the welding process is automatically
stopped due to overheating of the transformer.
The light extinguishes when the transformer
temperature has dropped to normal, and
welding can continue.
4. Welding time
With this control the welding time can be in-
finitely varied between 0.15 and 2.5 secs when
switch 1 is set to position Spot or Stitch.
CONTROL SWITCHES
5. Pause time
6. Burn-Back
7. Wire feed speed control
8. Switch for welding voltage
9. Main switch
10. Connection of welding hose
11. Inductance tappings
12. Plug
13. Automatic fuse 10 A
NB!
Pos. 12-13 is special equipment in 400 V standard
version.
11
With this control the pause time can be infinitely
varied when switch 1 is in position Stitch.
Variable time delay for wire to stop feeding after
voltage is switched off. This function is used to
prevent the wire sticking to the workpiece or
torch.
Variable between 0.05 and 0.5 secs.
For machines with "Gas-test".
When set at "Gas-test", the gas flows when the
torch trigger is pressed.
Please note that "Step 11" is a step without
function in Multimotive 220.
Multimotive 221: ON/OFF switch
Multimotive 220: ON/OFF switch + 2 rough
voltage steps.
Mains voltage tap 230 V AC intended for electric
hand tools.
For plug (pos. 12). The plug can be reclosed by
pushing the button.