On installation
On commissioning
In service
During cleaning
AVENTICS | EtherCAT | R412012792–BDL–001–AB
Always make sure the relevant system component is
W
not under pressure or voltage before assembly or
disassembly. Ensure that the system is prevented
from power restoration during assembly work.
Ground the modules and valve system. Observe the
W
following standards when installing the system:
– DIN EN 50178, VDE 0160 classification
– VDE 0100
Installation may only be performed in a voltage-free
W
and pressure-free state and only by a qualified
technician. In order to avoid accidents caused by
dangerous movements of the actuators, electrical
commissioning is to be carried out only in a pressure-
free state.
Do not put the system into operation before it is
W
completely assembled as well as correctly wired and
configured, and after it has been tested.
The device is subject to the restrictions in the IP65
W
protection class. Before commissioning, make sure
that all the connection seals and plugs are leaktight to
prevent fluids and foreign bodies from penetrating
the device.
Make sure that there is a sufficient exchange of air or
W
enough cooling if your valve system has any of the
following:
– Complete equipment
– Continuously loaded solenoid valves
Never use aggressive solvents or detergents. Only
W
clean the device using a slightly damp cloth. Only use
water to do this and, if necessary, a mild detergent.
3
Applications
The bus coupler is used to electrically control valves via
the real-time Ethernet technology EtherCAT.
The bus coupler is only intended for use as a slave in an
EtherCAT line in accordance with IEC 61158/61784.
53
Applications