Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical Data

Symbol
Measuring rate
measuring line length
Measuring impedance
Operating voltage
Working conditions
Operating altitude
Storage temperature
Weight
Dimensions (LxWxH)
Over-voltage category
Measurement tolerances
Statement of accuracy in ± (% of reading + display error in counts (= number of smallest points)).
The accuracy is valid for one year at a temperature of +23°C ± 5°C, and at a relative humidity of less than
75 %, non-condensing. Temperature coefficient: +0,1 x (specified accuracy)/1°C
Direct voltage
Range
600 mV
6 V
60 V
600 V
1,000 V
Overload protection 1,000 V; Impedance: 10 MΩ
Alternating voltage
Range
6 V
60 V
600 V
750 V
Frequency range 45 – 400 Hz; Overload protection 750 V
VC830: Effective average (RMS) at sinus voltage
VC850TrueRMS: Crest factor: max. 3.0
Permissible display error with an open measuring input: 2 counts
Permissible display error with a short-circuited measuring input: 20 counts
6000 counts
Approx. 3 measuring operations/second
Approx. 90 cm each
>10MΩ (V range)
9V block battery
0 to 30°C (<75%rF), >30 to 40°C (<50%rF)
max. 2,000 m
-10°C to +50°C
Approx. 380 g
185 x 91 x 43 (mm)
CAT III 1,000 V, CAT IV 600 V, contamination degree 2
Accuracy
±(0,5% + 3)
±(0,5% + 2)
±(0,8% + 3)
Accuracy
±(0,8% + 3)
±(1,0% + 5)
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.001 V
0.01 V
0.1 V
1 V
51