Technical Data - VOLTCRAFT CT-3 Notice D'emploi

Multimètre avec testeur de câbles
Masquer les pouces Voir aussi pour CT-3:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TECHNICAL DATA

Display
Auto-Power OFF
Input resistance
Operating voltage
Operating temperature
Storage temperature
Mass
Dimensions (LxWxH)
DMM measurement tolerances
Statement of accuracy in ± (% of reading (= reading = rdg) + display error in digits
(= dgt = no. of the smallest points)). The accuracy is valid for one year at a temper-
ature of +23°C ± 5°C, and at a relative humidity of less than 75 %, non-condensing.
Direct voltage range, overload protection 600 V
Range
200 mV
2 V
20 V
200 V
600 V
Alternating voltage range, overload protection 600 V
Range (50-60 Hz)
2 V
20 V
200 V
600 V
Resistance range
48
2000 digits
A signal sounds after about 15 minutes and the
device shuts down a minute later.
>7.5 MΩ
DMM: 3 V (2 x AAA)
Cable tester: 9 V compound
0°C to 40°C
-10°C to 50°C
Approximately 308 g
162 x 75 x 44 (mm)
Accuracy
±(0.8% + 4dgt)
±(1.3% + 4dgt)
Accuracy
±(1.3% + 6dgt)
±(1.8% + 10dgt)
Resolution
0.1 mV
1 mV
10 mV
100 mV
1 V
Resolution
1 mV
10 mV
100 mV
1 V
100 µA

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

12 19 31

Table des Matières