Capacity
Range
40 nF
400 nF
4 µF
40 µF
400 µF
4000 µF
Overload protection 1,000V
Frequency/Duty cycle
Range
10 Hz to 10 MHz
0,1 – 99,9 %
Overload protection 750V
Sensitivity: 200 mV; Amplitude max. 5 Veff (>5 V with adjustable impedance)
Temperature (VC850 only)
Range
-40 to -20 °C
-20 to 0 °C
0 to 100 °C
100 to 1,000 °C
* without sensor tolerance
Diode test
Test voltage
Approx. 3.7 V
Overload protection: 1,000 V
Acoustic continuity tester
Do not exceed the maximum permitted input values. Do not touch any circuits or
parts of circuits if they can have higher voltages than 25 V Acrms or 35 V DC.
Danger to life!
Accuracy
±(3.0% + 5) with REL function
±(3,0% + 5)
±(4,0% + 5)
Not specified
Accuracy
±(0,1% + 3)
Not specified
Accuracy*
-(8,0% + 5)
±(1,2% + 4)
±(1,2% + 3)
±(2,5% + 2)
Resolution:
0.001 V
<30 Ω continuous sound, test voltage: approx. 0.65 V/DC;
Overload protection 1,000 V
Resolution:
0.01 nF
0.1 nF
0.001 µF
0.01 µF
0.1 µF
1 µF
Resolution:
0.001 Hz to 0.01 MHz
0,1 %
Resolution:
1 °C