Di-VentiX™
7-3. COMMUNICATION PORTS & TALLY OUTPUTS
• REMOTE RS-232 (on DB 9 female connector)
Level:
RS-232.
Data Rate:
9600 Bauds, 8 data bits, 1 stop bit,
no parity bit, no flow control.
• TALLY OUT (on DB 9 female connector)
Rating:
20 Vdc MAX, 50 mA MAX (open collector).
• LAN (on RJ45 connector)
Protocol:
UDP (User Datagram Protocol) or TCP (Transmission
Control Protocol).
Data Rate:
10 / 100 Mbps.
LED functions (on RJ45 connector):
7-4. OPTIONAL AUDIO INPUTS (OPT-iX-A)
• 9 Balanced and unbalanced stereo inputs (on 5-pin MCO male connector).
• Vi = + 18 dBu (max).
• Zi = 20 kΩ unbalanced.
• Zi = 40 kΩ balanced.
7-5. OPTIONAL AUDIO OUTPUT (OPT-iX-A)
• 2 Balanced and unbalanced mono/stereo outputs (on 5-pin MCO male connector).
• Vo max:
Unbalanced = + 18 dBu (+12 dBu with 300Ω load).
Balanced = + 24 dBu (+18 dBu with 600Ω load).
• Zo = 600 Ω balanced.
• Zo = 300 Ω unbalanced.
• G = 0 dB nominal.
• G = + 6 dB / - ∞ adjustable with Master volume.
7-6. ENVIRONMENTAL
Power:
Storage Temperature:
Operating temperature:
Maximum ambient operating temperature:
Hygrometry:
Dimension:
Weight:
Chapter 7 : TECHNICAL SPECIFICATIONS (continued)
DB9 Female
connector
Top LED
OFF
OFF
ON
100 VAC to 240 VAC ; 50-60 Hz ; 130 watts, internal, auto-switchable.
-25 °C to +85 °C (-13 °F to +185 °F).
0 °C to 50 °C (32 °F to 122 °F).
< 40 °C ( < 104 °F).
10% to 80% (without condensation).
W 480 x D 420 x H 133 mm / 19"W x 16.5"D x 5.25"H.
(Compatible with a Standard 19" rack, Height = 3 U).
DVX8022:
8 kg / 17.6 lbs.
OPT-iX-A:
+ 0.5 kg / 1.1 lbs.
PIN #
FUNCTION
1
2
Tx (transmit data)
3
Rx (receive data)
4
reserved for manufacturer
5
6
7
8
reserved for manufacturer
9
Bottom LED
OFF
ON
100 BASE-T link.
OFF
10 BASE-T link.
tally # 1
Ground
tally # 2
NC
tally # 3
Meaning
No link
PAGE 67