3.2.3
Taring
3.2.4
Operating the totalising functions
3.2.5
Selection options for total display
3.2.6
Clip off factor when totalising
3.2.7
Automatic totalising
Taring functions same as for 3.1 Weighing and taring.
Press the F key to transfer the weight on the weighing platform to the total
memory.
The item counter and the consecutive number are incremented by 1.
Before requesting the next total, the scale must be clipped off at least to the clip
off factor defined in Setting mode.
A weight value of 0 or a total without clip off results in "Error 55 Place weight on
scale". If the clip off factor = 0, only a brief weight change is required.
Ending the totalising function
The totalising operation is terminated by pressing the key combination INFO,
F and Print. At the same time, the totals are printed out with the additional
information dependent on the print template, or they are transferred and deleted
as data record.
Function description in the manual.
- Display, print and clear total.
- Only display totals.
(no function when batching)
In Setting mode, you can define (see manual) whether the scale must be clipped
off each time you place an individual piece by 1 to 30 increments.
If the scale is not clipped off, the weight unit is not accepted in the total memory.
This prevents operations such as saving an item twice.