Maintenance

Cleaning the condensate receptacle

Cleaning and refilling the syphon

Inspection of combustion chamber

1
3
4
6
24
2
5
8
Cleaning the condensate receptacle

Disconnect the plug of the fluegas
temperature sensor (1);

Remove the condensate receptacle
(2);

Clean the receptacle;

Mount the condensate receptacle;

Connect the plug of the fluegas tem-
perature sensor.
Cleaning and refilling the syphon

Remove the syphon (3) from the con-
densate connection;

Clean and fill it with fresh water;

Mount the syphon back in the original
position.
Inspection of combustion chamber
For inspection of the combustion cham-
ber the mixing system and burner must
be disassembled.

Switch off the boiler and close the gas
supply;

Remove the electrical connection
from the fan and gas valve (4);

Remove the electrical connection
from the electrodes (5);

Undo the gas connection at the inlet
7
of the gas valve (6);

Disassemble the top plate incl. mixing
system (7);

Remove the burner from the
combustion chamber (8);

Inspect the combustion chamber and
clean it with a vacuumcleaner if
necessary;

Assemble all components in opposite
order;

Open the gas supply and check all
connections for gas leakage;

Switch on the boiler.