TANK EMPTYING
An automatic float shut-off system (25) turns off the vacuum system when the recovery tank is full.
The vacuum system shutdown is signalled by an increase in the vacuum system motor noise, moreover the floor is not dried.
CAUTION!
If the vacuum system turns off accidentally (for example, when the float is activated because of a sudden
machine movement), to resume the operation: turn off the machine with the function selection knob (31) turned
to "0", check that the float inside the grid (25) has gone down to the water level. Then turn on the vacuum
system by pressing the function selection knob (31).
When the recovery tank (23) is full, empty it as shown.
Solution and recovery tank emptying
1.
Check that the function selection knob (31) is turned to "0".
2.
Drive the machine to the appointed disposal area.
3.
Remove the transparent cover (24).
4.
Grasp the handle (A, Fig. 3) and lift the tank assembly (B).
5.
Empty the recovery tank (C). Then, rinse the tank with clean water.
6.
Open the plug (D) and drain the solution tank. Then, rinse the tank with clean water.
7.
Reinstall the tank assembly (22) on the machine frame and the transparent cover (23).
B
USER MANUAL
Figure 3
9099872000 - SCRUBTEC 337.2
C
A
ENGLISH
D
P100409
13