Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH
Machine speed adjustment
4.
The machine speed varies according to the type of floor to be cleaned and the choice of using the brush or the pad. If
necessary, it is possible to adjust the machine speed, according to the procedure shown in Maintenance chapter.
Battery discharge during operation
5.
Until the green LED (68) turns on in the first 5 seconds, the batteries allow to work normally. When the yellow and red LED turn
on in sequence, it is necessary to charge the battery as the machine residual autonomy is at the minimum level.
CAUTION!
Do not use the machine with discharged batteries, to avoid damaging the batteries and reducing the battery life.
MACHINE TRANSPORT/PARKING
To transport/park the machine, proceed as follows.
1.
Switch off the machine by turning the knob (62) to "0".
2.
Lift the squeegee (58).
3.
Keep the brush/pad-holder lifted with the handlebar and push the machine where necessary.
4.
Engage the positioning pin (24) and activate the machine parking device (23a) to keep the brush/pad-holder lifted (Fig. 5).
5.
When all the work is done, it is advisable to remove the brush/pad-holder from the deck (see the procedure in the next
paragraph), and engage it to the front holder (43).
Brush/pad-holder removal
Remove the brush/pad-holder deck by performing the following procedure:
1.
Turn the knob (62) to program (64).
2.
Lift the brush/pad-holder deck (10) by prying the handlebar (2).
3.
Press both the enabling push-button (69) and 3 times consequently the brush levers (70) and then wait that the brush
disengages from the drive hub.
4.
Turn the knob (62) to "0" position to switch off the machine.

TANK EMPTYING

An automatic float shut-off system (46) turns off the vacuum system when the recovery tank (30) is full.
The vacuum system shutdown, due to the recovery tank filling, is signalled by an increase in the vacuum system motor noise,
moreover the floor is not dried.
CAUTION!
If the vacuum system turns off accidentally (for example, when the float is activated because of a sudden
machine movement), to resume the operation: turn off the vacuum system by turning the knob (62) to "0", then
open the recovery tank cover (41) and check that the float inside the grid (46) has gone down to the water level.
Then close the recovery tank cover (6) and turn on the vacuum system by turning the knob (62) on the working
program.
When the recovery tank (30) is full, empty it according to the following procedure.