GB
PLU (Price Look Up) Function
The PLU function can store 100 PLU. They can be used for frequently sold goods, where the data (prices or/and
tare* depending on the setting in factory) can be looked up by simply entering the PLU number. The default is
price only.
*Preset tare is not permitted in EU countries.
☞ Store a PLU (unit price or/and tare)
Enter the required unit price or/and tare.
PLU
Press and hold the PLU key until a long beep is heard. In the weight display appears: "PLu".
Enter the PLU number (between 1 and 100) and wait for approx. 2 seconds, until the scale beeps twice.
☞ Recall a PLU (automatic search function off, refer to SET-UP, step 5)
Input the required PLU number, then press the PLU key. The stored data will appear in the display.
☞ Recall a PLU (automatic search function on, refer to SET-UP, step 5)
Input the required PLU number, the stored data will appear in the display.
Notice: To call PLU 12, press 1 and 2 within 2 seconds, if the 2 is not pressed within 2 seconds, the PLU
number 1 will be called up.
Preset
Key Function
The scale has 16 preset keys, which can store another 16 or 32 PLU and recall theses PLU directly.
☞
Store a PLU in a preset key
Enter the required unit price or/and tare.
~
Press and hold the required M-key until a long beep is heared, then two continous beeps will be heard to
M1
M16
indicate the data have been stored.
☞
Recall a PLU in a preset key
Press the required M-key, the data stored will appear in the display.
When double click function is on, referring to SET-UP, step 6, one preset key can store and recall 2 PLU. The
way to store and recall the first PLU is same as the operation in "Store a PLU in a preset key" and "Recall a PLU
in a preset key".
Store the second PLU in a preset key (double click function is on, refer to SET-UP, step 6)
☞
Enter the required unit price or/and tare.
Press and hold the required M-key until a long beep is heard, then press this M-key again and release it within
1 second, "L 2" will appear to show this data is stored by double-clicking M-key, and two beeps will finish the
storage.
Recall the second PLU in a Preset (double click function is on, refer to SET-UP, step 6)
☞
Double click the required M-key within 1 second, the "L 2" will be shown in the weight display for 1 second,
then the data stored by double-clicking this M-key will appear in the display.
Fix Key Function
Normally the tare and unit price will be cleared after each weighing, with key-FIX the tare and unit price can be
fixed.
FIX
Press the key-FIX and cursor FIX will be lit, the tare and unit price will remain until new value is entered.
ON/OFF
Press the key-FIX again to switch off the fix function.
8
METTLER TOLEDO
Tiger II