5.7 - Power Wiring Diagram
Refer to the Safety Information Manual and to the
electrical scheme supplied with the unit.
Electrical installation must be according to fig. 16.
Description
A
Power supply
Electrical heat er breaker (field supplied)
B
C Outdoor unit breaker (field supplied)
D Booster heater breaker (field supplied)*
Description
1 Outdoor unit power supply cable
Indoor unit power supply and
2
communication cable
Backup heater power supply cable
3
4 User interface cable
5 Booster heater power supply cable*
6 Booster heater activation cable*
7 Sanitary hot water sensor cable
8 Remote outdoor sensor cable
* Valid for domestic hot water tanks listed in paragraph Accessories.
If the user interface is installed in zone, install it in a place
which represents ambient room temperature. Avoid direct
contact or proximity with heat or cool sources.
Appropriate installation height is 1.5 m from the ground.
See electrical scheme for more information.
5.8 - Wiring Connection Diagram
• Units without backup heater, see fig. 17.
• Units with backup heater, single phase power supply,
see fig. 18 and fig. 20a.
• Units with backup heater, tri-phase power supply, see
fig. 19 and fig. 20c.
• Connection between Indoor and Outdoor units: see
fig. 20b.
80AW-065
M0
M3
M6
T6
3Ph+N –
-
1pH - 230V
400V
2 poles
2 poles
4 poles
-
20 A
32 A
16 A
2 poles, 16 A
2 poles, 16 A
80AW-065
Cable
Type
M0
M3
M6
H07 RN-F
3G x 2.5 mm
2
H07 RN-F
3G x 1 mm
2
3G x 4
3G x 6
H07 RN-F
-
mm
mm
2
2
FROH2R
4 x 0.75 mm
2
H05VV-F
3G x 2.5 mm
2
FROH2R
2 x 1 mm
2
FROH2R
2 x 0.5 mm
2
FROH2R
2 x 0.5 mm
2
80AW-115
M0
M3
M6
T6
-
1pH - 230V
3Ph+N – 400V
2 poles
2 poles
4 poles
-
20 A
32 A
16 A
2 poles, 25 A
2 poles, 16 A
80AW-115
T6
M0
M3
M6
3G x 4 mm
3G x 1 mm
5 x 4
mm
2
3G x 4
3G x 6
(L1, L2,
-
mm
mm
2
2
L3, N,
Y/G)
4 x 0.75 mm
3G x 2.5 mm
2 x 1 mm
2 x 0.5 mm
2 x 0.5 mm
5.8.1 - Terminal block description
See fig. 17,18,19.
Terminal
Description
Block
1 - 2 - 3
Indoor unit power supply and
communication cable
4 - 5
Pump cut off contact (EN1264-4)*
6 - N
Booster heater control* (domestic hot
water tank)
7 - 8 - N
Domestic hot water 3 way valve*
10 - 11
Domestic hot water tank sensor*
12 - 15
Hi energy rate input
13 - N
Multi-purpose output
14 - 15
System ON/OFF input
15
Common for dry contact input
W-C-G-Y
User interface placed on the unit or
removed from the unit and mounted
in zone
20 - 15
Heat/Cool thermostat input
21 - 15
Heat/Cool selection input
22 - 15
Domestic hot water input
Rc-Rh-G2-Y2
Additional user interface or 2 zone kit
connection
N
Neutral
31 - N
Boiler (only for units 80AW---M0)
* See paragraph Accessories.
80AW-150
T9
M0
T6
-
3Ph+N – 400V
4 poles
4 poles
-
20 A
16 A
4 poles, 25 A
2 poles, 16 A
80AW-150
T6
T9
M0
T6
5G x 2.5 mm
2
3G x 1 mm
2
5 x 4
5 x 6
5 x 4
mm
mm
mm
2
2
2
(L1, L2,
(L1, L2,
(L1, L2,
L3, N,
L3, N,
L3, N,
Y/G)
Y/G)
Y/G)
4 x 0.75 mm
2
3G x 2.5 mm
2
2 x 1 mm
2
2 x 0.5 mm
2
2 x 0.5 mm
2
Details
Output, 230 V, max 2 A
(inductive)
Output, 230 V, max 2 A
(inductive)
Input, Analog
Input, Dry Contact
Output, 230 V, max 2 A
(inductive)
Input, Dry Contact
Input, Dry Contact
Input, Dry Contact
Input, Dry Contact
Input, Dry Contact
Output, 230 V, max 2 A
(inductive)
T9
4 poles
20 A
T9
2
2
5 x 6
mm
2
(L1, L2,
L3, N,
Y/G)
2
2
2
2
2
29