Putting into operation
Attention: Before the first use fill in oil.
HP1100S / HP1300S
Starting the motor: Fig. 3.1, 3.2, 3.3, 3.4
1
Set the choke to ON (with warm motor to OPEN)
2
Open the gasoline tap
3
Move the gas lever to starting position.
4
Set the start switch to ON, forcefully pull the starter
cable
5
Move gas lever to working position, the vibratory plate
starts to work
6
Motor running, slowly open choke
7
Move gas lever to working position
8
Vibratory plate starts to work
HP1100S / HP1300S
-