electrical information
EN
5.2
battery back-up installation
WARNING
!
•
Ensure the gas and electrical power to the appliance is turned off.
•
Appliance may be hot. Do not service until the appliance has cooled.
note:
In the event of a power failure, your appliance can be operated using the battery back-up supplied.
A.
Before beginning installation, disconnect the gas and electrical power supply from the appliance.
B.
Locate the battery housing supplied in the manual baggie.
C.
Install four "AA" batteries (not supplied) into the battery housing, ensure the positive and negative ends
correspond with those identifi ed on the holder. (To open the battery housing, slide the back piece
upwards and off of the battery housing).
D.
Remove the safety barrier to easily access the control compartment.
E.
Attach the wire labelled "BATTERY" from the wiring harness, located in the control compartment of the
appliance, to the battery housing.
F.
Place the battery housing into the control compartment, ensuring that the battery housing is placed in a
clean and easily accessible location.
G.
Reinstall the safety barrier. The safety barrier must be installed at all times during the appliance operation.
H.
Turn the gas and electrical power back on to begin operating the appliance.
note:
Once the power has been restored, remove the batteries from the holder.
Red wire
40
W415-1613 / F / 03.12.19
Control module
Black wire
Battery housing